| Literature DB >> 15200876 |
Yukiko Wagatsuma1, Robert F Breiman, Anowar Hossain, Mahbubur Rahman.
Abstract
An outbreak of dengue fever occurred among employees of a recreation club in Bangladesh. Occupational transmission was characterized by a 12% attack rate, no dengue among family contacts, and Aedes vectors in club areas. Early recognition of the outbreak likely limited its impact.Entities:
Mesh:
Year: 2004 PMID: 15200876 PMCID: PMC3323095 DOI: 10.3201/eid1004.030330
Source DB: PubMed Journal: Emerg Infect Dis ISSN: 1080-6040 Impact factor: 6.883
Characteristics of 13 dengue fever patients a,b,c
| Case no. | Age | Sex | Mac ELISA (peak outbreak period; Oct 21, 2001)a | PCR (Oct 17, 2001; with fever within the past 5 days) | Mac ELISA (Nov 21–26, 2001) | Onset of illness | Occupation |
|---|---|---|---|---|---|---|---|
| 1 | 26 | Male | Primary | - | Primary | 01/10/01 | Assistant security |
| 2 | 35 | Male | Secondary | - | Secondary | 10/10/01 | Security guard |
| 3 | 40 | Male | Primary | Negative | Negative | 11/10/01 | Security guard |
| 4 | 26 | Male | Secondary | - | Secondary | 11/10/01 | Gardener |
| 5 | 24 | Male | Primary | Negative | Negative | 12/10/01 | Receptionist |
| 6 | 22 | Male | Secondary | Negative | Secondary | 13/10/01 | Tennis ball boy |
| 7 | 27 | Male | Negative | Negative | Secondary | 14/10/01 | Waiter |
| 8 | 33 | Male | Primary | - | Primary | 14/10/01 | Cook |
| 9 | 30 | Male | Primary | - | Negative | 15/10/01 | Baker |
| 10 | 38 | Male | - | - | Secondary | 15/10/01 | Laundry staff |
| 11 | 38 | Female | Secondary | - | Secondary | 16/10/01 | Laundry staff |
| 12 | 38 | Male | Negative | Den-3 | Primary | 17/10/01 | Confectioner |
| 13 | 34 | Male | - | - | Primary | 19/10/01 | Gardener |
aFever duration > 3 days and serologically confirmed. Those who reported in the table were only for those continuously worked from October 17 to November 2001 (4 employees were no longer working at the club and not available on Nov 21–26, 2001; their Mac ELISA results on October 17 included one specimen positive for primary infection and the others negative). bSerologic survey on Nov 21–26 indicated two more employees, not included in this table, who had dengue antibodies (one primary and one secondary pattern). They did not have symptoms; thus, they were not included as case-employees. cELISA, enzyme-linked immunosorbent assay; PCR, polymerase chain reaction.
FigureDates of onset for cases of dengue fever and other febrile illnesses among employees of the expatriate recreation club.
Illness reported among employees and family members during the outbreak period, September–October 2001
| Employee categories | Family members with history of febrile illnesses during outbreak period | Dengue laboratory test confirmation done for febrile illnesses among family members |
|---|---|---|
| 13 employees with confirmed dengue | 2.0% (1/51)a | No laboratory confirmation done |
| 76 employees who did not have dengue and did not have a febrile illness during outbreak period | 6.5% (14/215)a | 6 febrile patients had laboratory tests and 2 were serologically confirmed as dengue fever at commercial pathology laboratories |
| 11 employees who did not have dengue and who had a febrile illness during outbreak period | 14.3% (6/42)b | No laboratory confirmation done |
| Total employees = 100 | 6.8% (21/308)a |
aNumber of febrile illnesses/number of family members. bp = 0.04 when compared with the percentage of febrile illness among family members of case-patients.
Survey of wet containers for Aedes larvae within and outside of the club
| Place | Container type | No. of wet containers | No. of positive containers | No. of larvae | Mosquito species | ||
|---|---|---|---|---|---|---|---|
|
|
| Others | |||||
| Outside of premise boundary | Metallic drum cover | 26 | 20 | 364 | 103 | 261 | 0 |
| Outside of club building | Plastic glass | 1 | 1 | 19 | 0 | 19 | 0 |
| Manhole cover | 6 | 1 | 4 | 4 | 0 | 0 | |
| Inside of club building | No wet container found | 0 | 0 | 0 | 0 | 0 | 0 |
| Rooftop of club building | Stagnant water on rooftop floor | 1 | 1 | 5 | 5 | 0 | 0 |
| Total | 34 | 23a | 392 | 112 | 280 | 0 | |
a Overall container index (CI) was 68 (23/34 x 100).