Literature DB >> 15200545

The 'fixed performance' venturi: effect of downstream pressure on outflow and FIO2.

J G Jones1.   

Abstract

Fixed performance venturi devices should provide a predetermined oxygen concentration at an outflow which exceeds an adult's peak resting inspiratory flow rate (approximately 30 l.min(-1)). Campbell's original description mentioned the sensitivity of the venturi device to downstream resistance but gave no further details. This study examined outflow and oxygen concentration from the five standard venturi devices (24-60% O(2)) when downstream pressure increased. Outflow was exquisitely sensitive to small increases in pressure. The outflow at zero downstream pressure for the 24-40% O(2) venturi devices ranged from 40 to 50 l.min(-1) but only 2-3 mmH(2)O was needed to halve this flow and increase oxygen concentration. The 60% O(2) venturi delivered a maximum of only 30 l.min(-1) at zero downstream pressure and flow was reduced further by increasing this pressure. An increase in downstream pressure of only a few mmH(2)O increased oxygen concentration and decreased outflow of all the venturi devices tested, in most to less than normal peak tidal flow in adults.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15200545     DOI: 10.1111/j.1365-2044.2004.03754.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Effective and rapid technique to ensure uniform talc pleurodesis.

Authors:  Zeena Makhija; Ranjit Deshpande; Michael T Marrinan
Journal:  Gen Thorac Cardiovasc Surg       Date:  2010-11-11

Review 2.  Should We Use High-Flow Nasal Cannula in Patients Receiving Gastrointestinal Endoscopies? Critical Appraisals through Updated Meta-Analyses with Multiple Methodologies and Depiction of Certainty of Evidence.

Authors:  Chi Chan Lee; Teressa Reanne Ju; Pei Chun Lai; Hsin-Ti Lin; Yen Ta Huang
Journal:  J Clin Med       Date:  2022-07-03       Impact factor: 4.964

Review 3.  Established severe BPD: is there a way out? Change of ventilatory paradigms.

Authors:  Richard Sindelar; Edward G Shepherd; Johan Ågren; Howard B Panitch; Steven H Abman; Leif D Nelin
Journal:  Pediatr Res       Date:  2021-05-19       Impact factor: 3.756

Review 4.  Non-invasive Respiratory Support in COVID-19: A Narrative Review.

Authors:  Manel Luján; Javier Sayas; Olga Mediano; Carlos Egea
Journal:  Front Med (Lausanne)       Date:  2022-01-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.