The upgraded Finapres 2300e. A clinical evaluation of a continuous noninvasive blood pressure monitor.

R D Jones1, A G Brown, C J Roulson, I D Smith, S C Chan.   

Abstract

Measurements from the upgraded Finapres 2300e continuous noninvasive blood pressure monitor, the Finapres 2300 and Colin oscillometric noninvasive blood pressure monitor were compared with invasive arterial line blood pressure readings. Fifteen young Chinese patients undergoing elective spinal surgery of more than 2 h duration had contemporaneous blood pressure measurements digitally recorded every minute. Data were analysed using methods described by Bland and Altman to assess agreement of noninvasive devices with an arterial line. Results showed that although the Finapres 2300e was significantly more accurate than the Finapres 2300 and Colin noninvasive blood pressure monitors it could not be recommended as a substitute for continuous arterial line blood pressure monitoring. Both Finapres devices demonstrated reductions in accuracy related to time (drift) and over-read diastolic and mean pressures by 5-8 mmHg throughout the range of mean arterial line pressures (bias). The Colin was consistently less accurate than the Finapress monitors and performed worst at low mean arterial line pressures.

Entities:  

Mesh:

Year:  1992        PMID: 1519723     DOI: 10.1111/j.1365-2044.1992.tb02396.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Evaluation of noninvasive blood pressure recording by photoplethysmography in clinical studies using angiotensin challenges.

Authors:  T Buclin; C Buchwalder-Csajka; H R Brunner; J Biollaz
Journal:  Br J Clin Pharmacol       Date:  1999-10       Impact factor: 4.335

2.  Reproducibility of the heart rate variability responses to graded lower body negative pressure.

Authors:  Kichang Lee; Dwayne B Buchanan; Alison B Flatau; Warren D Franke
Journal:  Eur J Appl Physiol       Date:  2004-03-13       Impact factor: 3.078

3.  Validity of auscultatory and Penaz blood pressure measurements during profound heat stress alone and with an orthostatic challenge.

Authors:  Matthew S Ganio; R Matthew Brothers; Rebekah A I Lucas; Jeffrey L Hastings; Craig G Crandall
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2011-08-10       Impact factor: 3.619

Review 4.  Current state of noninvasive, continuous monitoring modalities in pediatric anesthesiology.

Authors:  Jan J van Wijk; Frank Weber; Robert J Stolker; Lonneke M Staals
Journal:  Curr Opin Anaesthesiol       Date:  2020-12       Impact factor: 2.733

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.