Literature DB >> 15193721

CE versus HPLC for the dissolution test in a pharmaceutical formulation containing acetaminophen, phenylephrine and chlorpheniramine.

A Marín1, C Barbas.   

Abstract

A new polar reverse phase stationary phase has permitted our group to develop and validate an isocratic HPLC method for the simultaneous determination of acetaminophen, phenylephrine and chlorpheniramine in capsules as pharmaceutical formulation after their dissolution test. Final optimised chromatographic conditions employed a Supelco Discovery HS PEG column (polyethylene glycol), 5 microm, 15 cm x 0.46 cm. The mobile phase was 20 mM phosphate buffer at pH 7.0/acetonitrile 80:20 (v/v) at a flow rate of 1 ml/min. UV detection was performed at 210 nm for phenylephrine and chlorpheniramine and at 305 nm for acetaminophen. On the other hand, to evaluate the capability of CE to work in a routine analytical method fulfilling the pharmaceutical requirements and to study the behaviour of the technique with these compounds, we developed a CE method with the same objective. Normal and reverted polarity, the pH and concentration of the buffer, and the presence and concentration of surfactants were assayed. Forty millimolar phosphate buffer at pH 6.20 with 0.5 mM SDS at 30k V in an uncoated silica capillary provided a runtime of 4.5 min to separate the three analytes and the excipients. Moreover, parameters affecting precision in CE, such as the injection of buffer after the sample to refill the capillary were also tested. After development, the validation was performed in parallel for HPLC and CE with the same standards and samples to avoid differences due to the manipulation. The validation parameters of both techniques were adequate for the intended purpose. Copyright 2004 Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15193721     DOI: 10.1016/j.jpba.2004.03.003

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  3 in total

1.  Development and validation of a dissolution test for meloxicam and pridinol mesylate from combined tablet formulation.

Authors:  S E Vignaduzzo; P M Castellano; T S Kaufman
Journal:  Indian J Pharm Sci       Date:  2010-03       Impact factor: 0.975

2.  Simultaneous spectrophotometric determination of paracetamol, phenylephrine and chlropheniramine in pharmaceuticals using chemometric approaches.

Authors:  M R Khoshayand; H Abdollahi; A Ghaffari; M Shariatpanahi; H Farzanegan
Journal:  Daru       Date:  2010       Impact factor: 3.117

3.  Sensing of chlorpheniramine in pharmaceutical applications by sequential injector coupled with potentiometer.

Authors:  Tawfik A Saleh
Journal:  J Pharm Anal       Date:  2011-10-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.