Literature DB >> 15192523

[Detection of liver metastases in colorectal cancer on chemotherapy. Comparative study between MRI with teslascan and computed tomography with intravenous contrast media].

C Beziat1, F Pilleul, D Yzebe, C Lombard-Bohas, C Mercier, P J Valette.   

Abstract

OBJECTIVE: To compare MRI of the liver with mangafodipir trisodium (MnDPDP) and computed tomography with intravenous contrast media in the follow-up of liver metastases in patient on chemotherapy for colorectal carcinoma.
MATERIALS AND METHODS: This was a prospective study with patients on chemotherapy for liver metastases from colorectal cancer. Patients underwent both contrast-enhanced helical CT using 2 cc/kg contrast at 3 cc/sec and mangafodipir trisodium-enhanced MR imaging at 1.5 T using 2-3 cc/min contrast at 5 micro mol/kg within a two week interval. Two experienced radiologists independently reviewed all scans in a blinded fashion and recorded image quality as well as presence and number of liver lesions. Statistical analysis was performed using the wilcoxon signed rank test.
RESULTS: All examinations were of good quality. A total of 71 lesions were detected at CT, with 69 lesions consistent with metastases and 2 lesions consistent with cysts. A total of 98 lesions were detected at MRI, with 97 consistent with metastases and 1 lesion consistent with a cyst. T1 weighted images with MnDPDP significantly detected two additional lesions compared to CT (p<0.05). No significant difference was demonstrated between T1 weighted images without MnDPDP and CT or between T2 weighted images and CT.
CONCLUSION: Magnetic resonance imaging with MnDPDP is significantly more sensitive than unenhanced MRI and helical CT for the follow-up of liver lesions.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15192523     DOI: 10.1016/s0221-0363(04)97583-x

Source DB:  PubMed          Journal:  J Radiol        ISSN: 0221-0363


  3 in total

1.  Manganese-Enhanced MRI in Patients with Multiple Sclerosis.

Authors:  D J Suto; G Nair; D M Sudarshana; S U Steele; J Dwyer; E S Beck; J Ohayon; H McFarland; A P Koretsky; I C M Cortese; D S Reich
Journal:  AJNR Am J Neuroradiol       Date:  2020-08-06       Impact factor: 3.825

2.  Detection of colorectal hepatic metastases using MnDPDP MR imaging and diffusion-weighted imaging (DWI) alone and in combination.

Authors:  D M Koh; G Brown; A M Riddell; E Scurr; D J Collins; S D Allen; I Chau; D Cunningham; N M deSouza; M O Leach; J E Husband
Journal:  Eur Radiol       Date:  2008-01-12       Impact factor: 5.315

Review 3.  Surgical treatment of liver tumors - own experience and literature review.

Authors:  Aliaksandr Tarasik; Jerzy Jaroszewicz; Marcin Januszkiewicz
Journal:  Clin Exp Hepatol       Date:  2017-01-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.