Literature DB >> 15191761

Comparison of two treatment techniques for breast irradiation including internal mammary nodes.

Sara J Allen1, Eric E Klein, Martha Michaletz-Lorenz, Jian-Yue Jin.   

Abstract

Techniques to treat breast cancer inclusive of the internal mammary lymph node chain (IMC) vary. This study compared a presently accepted technique implemented at the Radiation Oncology Department at Barnes-Jewish Hospital/Washington University School of Medicine (BJ/WU) to a proposed technique for irradiation of breast tissue and the IMC. The present technique consists of parallel-opposed breast tangential beams in combination with photon and electron IMC fields angled along the chest wall. The proposed method involves a wide medial tangent field covering the IMC, with an angled electron IMC field for a portion of the treatment regimen and an opposed lateral breast-only tangent. This technique uses a multileaf collimation (MLC) reduction to treat the IMC aspect following the wide medial tangent, to supplement the IMC to a tumorcidal dose. These techniques were compared by reviewing isodoses with subsequent isodensity confirmation. Computerized tomography imaging sets of patients with various body types (chest wall, small and large breasts) for left-sided tumors were planned using a three-dimensional treatment planning system (FOCUS, Computerized Medical Systems). The plans were evaluated by comparing irradiated heart and lung volumes and the respective dose distribution at the IMC field/medial tangent junction. Specific treatment aids and photon/electron energies were employed to produce desirable isodose distributions, with a dose prescription of 4680-cGy total dose. The efficiency of the radiation treatments itself was also evaluated. The proposed technique decreases treatment time by eliminating an additional IMC field that involves repositioning and placement of a block. Phantom-based film isodensity measurements were evaluated to validate the calculated dosimetry for these techniques.

Entities:  

Mesh:

Year:  2004        PMID: 15191761     DOI: 10.1016/j.meddos.2004.03.009

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  3 in total

1.  Quantification and reduction of peripheral dose from leakage radiation on Siemens Primus accelerators in electron therapy mode.

Authors:  Collins Yeboah; Alex Karotki; Dylan Hunt; Rick Holly
Journal:  J Appl Clin Med Phys       Date:  2010-06-15       Impact factor: 2.102

2.  Radiation pneumonitis in breast cancer patients who received radiotherapy using the partially wide tangent technique after breast conserving surgery.

Authors:  Yoonsun Chung; Hong In Yoon; Yong Bae Kim; Seung Kwon Ahn; Ki Chang Keum; Chang-Ok Suh
Journal:  J Breast Cancer       Date:  2012-09-28       Impact factor: 3.588

3.  Comparison of Photon-electron and Photon Radiotherapy for Supraclavicular Lymph Nodes of Mastectomy Patients with Left-sided Breast Cancer.

Authors:  Mehran Mohseni; Fatholah Mohaghegh; Nasrin Robatmili; Mohammad Reza Bayatiani; Fatemeh Seif; Nayyer Sadat Mostafavi
Journal:  J Cancer Prev       Date:  2020-03-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.