Literature DB >> 15191172

Comparison of real and computer-simulated outcomes of LASIK refractive surgery.

Daniel Cano1, Sergio Barbero, Susana Marcos.   

Abstract

Computer simulations of alternative LASIK ablation patterns were performed for corneal elevation maps of 13 real myopic corneas (range of myopia, -2.0 to -11.5 D). The computationally simulated ablation patterns were designed with biconic surfaces (standard Munnerlyn pattern, parabolic pattern, and biconic pattern) or with aberrometry measurements (customized pattern). Simulated results were compared with real postoperative outcomes. Standard LASIK refractive surgery for myopia increased corneal asphericity and spherical aberration. Computations with the theoretical Munnerlyn ablation pattern did not increase the corneal asphericity and spherical aberration. The theoretical parabolic pattern induced a slight increase of asphericity and spherical aberration, explaining only 40% of the clinically found increase. The theoretical biconic pattern controlled corneal spherical aberration. Computations showed that the theoretical customized pattern can correct high-order asymmetric aberrations. Simulations of changes in efficiency due to reflection and nonnormal incidence of the laser light showed a further increase in corneal asphericity. Consideration of these effects with a parabolic pattern accounts for 70% of the clinical increase in asphericity.

Entities:  

Mesh:

Year:  2004        PMID: 15191172     DOI: 10.1364/josaa.21.000926

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  8 in total

1.  The effect of optical zone decentration on lower- and higher-order aberrations after photorefractive keratectomy in a cat model.

Authors:  Jens Bühren; Geunyoung Yoon; Shawn Kenner; Scott MacRae; Krystel Huxlin
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-12       Impact factor: 4.799

2.  Analytical optimization of the ablation efficiency at normal and non-normal incidence for generic super Gaussian beam profiles.

Authors:  Samuel Arba-Mosquera; Shwetabh Verma
Journal:  Biomed Opt Express       Date:  2013-07-24       Impact factor: 3.732

3.  Visual outcome after correcting the refractive error of large pupil patients with wavefront-guided ablation.

Authors:  Mounir A Khalifa; Waleed A Allam; Mohamed S Shaheen
Journal:  Clin Ophthalmol       Date:  2012-12-03

4.  Corneal topography from spectral optical coherence tomography (sOCT).

Authors:  Sergio Ortiz; Damian Siedlecki; Pablo Pérez-Merino; Noelia Chia; Alberto de Castro; Maciej Szkulmowski; Maciej Wojtkowski; Susana Marcos
Journal:  Biomed Opt Express       Date:  2011-11-04       Impact factor: 3.732

5.  Customized Finite Element Modelling of the Human Cornea.

Authors:  Irene Simonini; Anna Pandolfi
Journal:  PLoS One       Date:  2015-06-22       Impact factor: 3.240

6.  Comparison of Corneal Wavefront-optimized and Wavefront-guided Alcohol-assisted Photorefractive Keratectomy Using Schwind Amaris 750S Laser for Myopia.

Authors:  Min Ji Kang; Jehyung Hwang; So Hyang Chung
Journal:  Korean J Ophthalmol       Date:  2020-06

Review 7.  Outcome comparison between wavefront-guided and wavefront-optimized photorefractive keratectomy: A systematic review and meta-analysis.

Authors:  Khaled M Hamam; Mohamed I Gbreel; Randa Elsheikh; Amira Y Benmelouka; Yassamine Ouerdane; Amr K Hassan; Aboalmagd Hamdallah; Ahmed B Elsnhory; Anas Z Nourelden; Ahmed T Masoud; Asmaa A Ali; Khaled M Ragab; Ahmed M Ibrahim
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

8.  Refractive outcomes of an advanced aspherically optimized profile for myopia corrections by LASIK: a retrospective comparison with the standard aspherically optimized profile.

Authors:  Bertram Meyer; Georg Sluyterman van Langeweyde; Matthias Wottke
Journal:  Clin Ophthalmol       Date:  2015-02-23
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.