How the implementation of an in-vivo dosimetry protocol improved the dose delivery accuracy in head and neck radiotherapy.

J Malicki1, M Litoborski, J Kierzkowski, G Kosicka.   

Abstract

Doses were measured in-vivo at the entrance using semiconductor detectors for patients with head and neck tumors. Regular measurements started on January 1st and continued till June 30th, 2001. Then the evaluation of the discrepancies between the measured and calculated doses was made, and it resulted in the changes in the protocol of in-vivo dosimetry made effective by February 1st, 2002. The collection of the measurements was censored by January 30th 2003. The number of patients in the two groups was 285 (1st) and 407 (2nd), respectively. The results exhibited the not-Gaussian distribution of the measured doses in both groups. The average number of dose checks per patient increased from 4.9 to 6.0 (1st vs. 2nd group). The mean relative difference between the measured and calculated doses was: -1.5% vs. -0.5%, whereas the standard deviation (1 SD) decreased from 6.1% to 5.6%. The Mann-Whitney U test detected a significant difference between the 1st and the 2nd group (p=0.00000), which justified the conclusion that the changes implemented in the protocol improved dose delivery accuracy and reproducibility of irradiation.

Entities:  

Mesh:

Year:  2004        PMID: 15190426

Source DB:  PubMed          Journal:  Neoplasma        ISSN: 0028-2685            Impact factor:   2.575


  5 in total

Review 1.  Organizational, technical, physical and clinical quality standards for radiotherapy.

Authors:  Marta Bogusz-Czerniewicz; Daniel Kaźmierczak
Journal:  Rep Pract Oncol Radiother       Date:  2012-06-03

2.  Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT.

Authors:  Magdalena Peszynska-Piorun; Julian Malicki; Wojciech Golusinski
Journal:  Radiol Oncol       Date:  2012-11-09       Impact factor: 2.991

3.  On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator.

Authors:  Suman Kumar Putha; P U Saxena; S Banerjee; Challapalli Srinivas; B M Vadhiraja; Ramamoorthy Ravichandran; Mary Joan; K Dinesh Pai
Journal:  J Med Phys       Date:  2016 Oct-Dec

4.  Clinical quality standards for radiotherapy.

Authors:  Marta Bogusz-Czerniewicz
Journal:  Contemp Oncol (Pozn)       Date:  2012-02-29

5.  Quality management system in radiotherapy in the light of regulations applicable in Poland.

Authors:  Marta Bogusz-Czerniewicz
Journal:  Contemp Oncol (Pozn)       Date:  2012-05-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.