Literature DB >> 15186617

Ultrasound-guided fine-needle capillary biopsy of thyroid nodules, coupled with on-site cytologic review, improves results.

G Ceresini1, L Corcione, S Morganti, B Milli, L Bertone, R Prampolini, S Petrazzoli, M Saccani, G P Ceda, G Valenti.   

Abstract

Fine-needle aspiration biopsy represents the most reliable test for cytologic evaluation of thyroid nodules. However, inadequate samples may occur leading to a repetition of the procedure with the consequence of patients' discomfort and poor compliance. In this paper, we present results from biopsy of thyroid nodules obtained by combining: (1) ultrasound (US) guidance, (2) no-aspiration technique, and (3) on-site review of specimens. A total of 465 nodules were biopsied in 307 patients. Solitary nodules and multinodular goiter were present in 36.8% and 63.1% of patients, respectively. After collection, each sample was smeared in duplicates, one of which was stained with hematoxylin and checked on-site by a cytopathologist. In cases of inadequate smears, biopsies were immediately repeated. All slides were then processed for final cytologic results, which were reported as benign in 427 nodules (91.8%), malignant in 12 nodules (2.5%), with follicular proliferation or suspicious for malignancy in 23 nodules (4.9%). Inadequate final cytology was reported in 3 nodules (0.6%). No statistically significant relationship was found between nodule size and adequacy of specimens. We conclude that the combination of US guidance, capillary collection with no-aspiration technique, and on-site review of slides, characterizes an advantageous method for thyroid nodule fine-needle biopsy.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15186617     DOI: 10.1089/105072504774193230

Source DB:  PubMed          Journal:  Thyroid        ISSN: 1050-7256            Impact factor:   6.568


  10 in total

1.  Comparison of sample adequacy, pain-scale ratings, and complications associated with ultrasound-guided fine-needle aspiration of thyroid nodules between two radiologists with different levels of experience.

Authors:  Yoo Jin Lee; Dong Wook Kim; Soo Jin Jung
Journal:  Endocrine       Date:  2013-02-21       Impact factor: 3.633

Review 2.  A systematic review of ultrasound-guided FNA of lesions in the head and neck--focusing on operator, sample inadequacy and presence of on-spot cytology service.

Authors:  A Ganguly; G Burnside; P Nixon
Journal:  Br J Radiol       Date:  2014-09-23       Impact factor: 3.039

3.  A Comparative Study on Fine Needle Aspiration Cytology versus Fine Needle Capillary Cytology in Thyroid Nodules.

Authors:  Leo F Tauro; Geover J Lobo; Hilda Fernandes; Celine George; P Sathyamoorthy Aithala; Divakar Shenoy; Prathvi Shetty
Journal:  Oman Med J       Date:  2012-03

4.  Risk of Malignancy in Thyroid Nodules with Non-Diagnostic Fine-Needle Aspiration: A Retrospective Cohort Study.

Authors:  Ana E Espinosa De Ycaza; Kathleen M Lowe; Diana S Dean; M Regina Castro; Vahab Fatourechi; Mabel Ryder; John C Morris; Marius N Stan
Journal:  Thyroid       Date:  2016-10-05       Impact factor: 6.568

5.  The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography-guided fine-needle aspiration biopsy of thyroid nodules.

Authors:  Mehmet Fatih İnci; Fuat Özkan; Mürvet Yüksel; İsmail Şalk; Murat Şahin
Journal:  Endocrine       Date:  2012-09-06       Impact factor: 3.633

Review 6.  Ultrasound-guided fine needle aspiration of thyroid nodules: a consensus statement by the korean society of thyroid radiology.

Authors:  Young Hen Lee; Jung Hwan Baek; So Lyung Jung; Jin Young Kwak; Ji-hoon Kim; Jung Hee Shin
Journal:  Korean J Radiol       Date:  2015-02-27       Impact factor: 3.500

7.  Repeated nondiagnostic result of thyroid fine-needle aspiration biopsy.

Authors:  Klaudia Ziemiańska; Janusz Kopczyński; Aldona Kowalska
Journal:  Contemp Oncol (Pozn)       Date:  2017-01-12

8.  Ultrasound-guided fine-needle aspiration biopsy of thyroid nodules smaller than 5 mm in the maximum diameter: assessment of efficacy and pathological findings.

Authors:  Dong Wook Kim; Auh Whan Park; Eun Joo Lee; Hye Jung Choo; Sang Hyo Kim; Sang Hyub Lee; Jae Wook Eom
Journal:  Korean J Radiol       Date:  2009-08-25       Impact factor: 3.500

9.  Malignancy risk analysis in patients with inadequate fine needle aspiration cytology (FNAC) of the thyroid.

Authors:  Talib Al Maqbali; Miroslav Tedla; Martin O Weickert; Hisham Mehanna
Journal:  PLoS One       Date:  2012-11-19       Impact factor: 3.240

10.  Contrast-enhanced ultrasonography features of papillary thyroid carcinoma for predicting cervical lymph node metastasis.

Authors:  Ying Liu; Hong Zhou; Peng Yang; Yang Zhou; Jian Wu; Changyu Chen; Ming Ye; Jing Luo
Journal:  Exp Ther Med       Date:  2017-09-01       Impact factor: 2.447

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.