Literature DB >> 15183438

The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci.

Tammy L Haut Donahue1, M L Hull, Mark M Rashid, Christopher R Jacobs.   

Abstract

In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements have been studied. A number of biomechanical criteria may be important for a meniscal replacement to restore normal tibiofemoral contact pressure in the knee joint and hence be clinically successful. One of these criteria is geometric similarity. The objectives of the current study were to: determine the sensitivity of the contact variables of the tibial plateau to the transverse depth and width of both the lateral and medial menisci; determine the sensitivity of the contact variables of the tibial plateau to the cross-sectional width and height of the lateral and medial menisci; and determine the tolerances on each of the four parameters for both menisci. To satisfy these objectives, a previously developed finite element model of the tibiofemoral joint was used to compute the contact pressure distribution on the tibial plateau. The effect of the above-mentioned geometric parameters on the contact behavior was studied by perturbing the finite element model. Results showed that the contact variables are similarly sensitive to both the transverse and cross-sectional parameters of the menisci. Additionally the medial meniscal parameters have a greater effect on the contact variables than do the lateral meniscal parameters. Finally, less than a 0.5 mm change in the medial meniscal height and greater than a 1 mm change in the lateral meniscal height could be tolerated before the relative difference in the contact variables from those for the original geometry exceeded 10%. Thus in the design or selection of meniscal replacements, each of the four parameters should be measured when sizing a replacement tissue. Also tighter tolerances should be placed on the medial meniscal parameters compared to the lateral meniscal parameters.

Entities:  

Mesh:

Year:  2004        PMID: 15183438     DOI: 10.1016/j.orthres.2003.12.010

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  27 in total

Review 1.  Verification, validation and sensitivity studies in computational biomechanics.

Authors:  Andrew E Anderson; Benjamin J Ellis; Jeffrey A Weiss
Journal:  Comput Methods Biomech Biomed Engin       Date:  2007-06       Impact factor: 1.763

2.  Quantification of meniscal volume by segmentation of 3T magnetic resonance images.

Authors:  Megan E Bowers; Glenn A Tung; Braden C Fleming; Joseph J Crisco; Jesus Rey
Journal:  J Biomech       Date:  2007-03-27       Impact factor: 2.712

3.  Three-dimensional fibril-reinforced finite element model of articular cartilage.

Authors:  L P Li; J T M Cheung; W Herzog
Journal:  Med Biol Eng Comput       Date:  2009-03-06       Impact factor: 2.602

4.  Computational model-based probabilistic analysis of in vivo material properties for ligament stiffness using the laxity test and computed tomography.

Authors:  Kyoung-Tak Kang; Sung-Hwan Kim; Juhyun Son; Young Han Lee; Heoung-Jae Chun
Journal:  J Mater Sci Mater Med       Date:  2016-10-27       Impact factor: 3.896

Review 5.  Subject-specific analysis of joint contact mechanics: application to the study of osteoarthritis and surgical planning.

Authors:  Corinne R Henak; Andrew E Anderson; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

6.  In-vivo time-dependent articular cartilage contact behavior of the tibiofemoral joint.

Authors:  A Hosseini; S K Van de Velde; M Kozanek; T J Gill; A J Grodzinsky; H E Rubash; G Li
Journal:  Osteoarthritis Cartilage       Date:  2010-04-29       Impact factor: 6.576

7.  3D geometry analysis of the medial meniscus--a statistical shape modeling approach.

Authors:  A C T Vrancken; S P M Crijns; M J M Ploegmakers; C O'Kane; T G van Tienen; D Janssen; P Buma; N Verdonschot
Journal:  J Anat       Date:  2014-07-23       Impact factor: 2.610

8.  Using a statistically calibrated biphasic finite element model of the human knee joint to identify robust designs for a meniscal substitute.

Authors:  Erin R Leatherman; Hongqiang Guo; Susannah L Gilbert; Ian D Hutchinson; Suzanne A Maher; Thomas J Santner
Journal:  J Biomech Eng       Date:  2014-07       Impact factor: 2.097

9.  A statistically-augmented computational platform for evaluating meniscal function.

Authors:  Hongqiang Guo; Thomas J Santner; Tony Chen; Hongsheng Wang; Caroline Brial; Susannah L Gilbert; Matthew F Koff; Amy L Lerner; Suzanne A Maher
Journal:  J Biomech       Date:  2015-02-26       Impact factor: 2.712

10.  Osteochondral grafting: effect of graft alignment, material properties, and articular geometry.

Authors:  Darryl D D'Lima; Peter C Chen; Clifford W Colwell
Journal:  Open Orthop J       Date:  2009-08-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.