Strain and force transducers used in human and veterinary tendon and ligament biomechanical studies.

Bérangère Ravary1, Philippe Pourcelot, Claude Bortolussi, Stanislas Konieczka, Nathalie Crevier-Denoix.   

Abstract

Biomechanical studies often aim at determining the contribution (in terms of load or strain) of a tendon or ligament in posture, gesture or locomotion. To this end, many transducers have been developed since 30 years. These devices implanted within or attached to the inside of the tendon or ligament must be compliant enough to measure in vivo the tissue load or strain without interfering with the movement of man or animals. They can be transducers with variation of electrical resistance (liquid metal strain gauge, buckle transducer, implantable force transducer and pressure transducer), variation of magnetic field (Hall effect transducer) and variation of light flow (optic fibre). Their use requires surgery in order to implant them and it is limited in time because of their invasive character and the development of fibrous healing reactions. Besides, the transducer dimensions and its position in the tendon can influence the transducer output signal. Moreover, the latter may not reflect the behaviour of the tendon as a whole but only locally. In addition, a calibration is required in order to convert the output signal into a strain or a force. In animals, this calibration is generally made by a post-mortem procedure on dissected anatomical specimens; in man, an indirect calibration procedure using inverse dynamic calculations is generally performed. However, the calibration conditions cannot reproduce exactly the in vivo conditions. So far, only invasive transducers have allowed to measure strain or force in tendons with all constraints and limits mentioned above. Copyright 2004 Elsevier Ltd.

Entities:  

Mesh:

Year:  2004        PMID: 15182978     DOI: 10.1016/j.clinbiomech.2004.01.008

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  9 in total

1.  The 3D in vivo Achilles' tendon moment arm, quantified during active muscle control and compared across sexes.

Authors:  Frances T Sheehan
Journal:  J Biomech       Date:  2011-12-03       Impact factor: 2.712

2.  ShearWave elastography: repeatability for measurement of tendon stiffness.

Authors:  C D Peltz; J A Haladik; G Divine; D Siegal; M van Holsbeeck; M J Bey
Journal:  Skeletal Radiol       Date:  2013-05-03       Impact factor: 2.199

3.  3D-printed biomaterials with regional auxetic properties.

Authors:  John J Warner; Allison R Gillies; Henry H Hwang; Hong Zhang; Richard L Lieber; Shaochen Chen
Journal:  J Mech Behav Biomed Mater       Date:  2017-05-19

4.  Identification of spinal tissues loaded by manual therapy: a robot-based serial dissection technique applied in porcine motion segments.

Authors:  Gregory N Kawchuk; Alejandro Carrasco; Grayson Beecher; Darrell Goertzen; Narasimha Prasad
Journal:  Spine (Phila Pa 1976)       Date:  2010-10-15       Impact factor: 3.468

5.  Coordinated, multi-joint, fatigue-resistant feline stance produced with intrafascicular hind limb nerve stimulation.

Authors:  R A Normann; B R Dowden; M A Frankel; A M Wilder; S D Hiatt; N M Ledbetter; D A Warren; G A Clark
Journal:  J Neural Eng       Date:  2012-03-14       Impact factor: 5.379

6.  MM-MRE: a new technique to quantify individual muscle forces during isometric tasks of the wrist using MR elastography.

Authors:  Andrea Zonnino; Daniel R Smith; Peyton L Delgorio; Curtis L Johnson; Fabrizio Sergi
Journal:  IEEE Int Conf Rehabil Robot       Date:  2019-06

7.  Influence of muscle groups' activation on proximal femoral growth tendency.

Authors:  Priti Yadav; Sandra J Shefelbine; Eva Pontén; Elena M Gutierrez-Farewik
Journal:  Biomech Model Mechanobiol       Date:  2017-06-22

8.  Estimation of absolute states of human skeletal muscle via standard B-mode ultrasound imaging and deep convolutional neural networks.

Authors:  Ryan J Cunningham; Ian D Loram
Journal:  J R Soc Interface       Date:  2020-01-29       Impact factor: 4.118

Review 9.  Modelling and in vivo evaluation of tendon forces and strain in dynamic rehabilitation exercises: a scoping review.

Authors:  Adrian Escriche-Escuder; Antonio I Cuesta-Vargas; Jose Casaña
Journal:  BMJ Open       Date:  2022-07-25       Impact factor: 3.006

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.