Literature DB >> 15180231

Comparison of various vacuum mixing systems and bone cements as regards reliability, porosity and bending strength.

Hans Mau1, Katrin Schelling, Christian Heisel, Jian-Shang Wang, Steffen J Breusch.   

Abstract

BACKGROUND: There are several vacuum mixing systems on the market which are arbitrarily used with various bone cements in clinical work. Hardly any studies have been done on the performance and handling of these systems in combination with different cement brands.
MATERIAL AND METHODS: We therefore tested 6 vacuum mixing systems (Palamix, Summit, Cemvac, Optivac, Vacumix, MixOR) in combination with 6 cement brands (Palacos R, Simplex P, CWM 1, CWM 2000, Palamed G, VersaBond) concerning their reliability, user-friendliness, porosity and bending strength.
RESULTS: Our study indicated that each system has weak points. The preparation of the mixed cement for gun injection can present problems. If cement collection under vacuum fails, porosity is increased. Manual collection without a vacuum carries the risk of intermixing air. For comfortable and effective retrograde cement application, cement guns should have a stable connection with the cartridge and a high piston stroke. There are marked differences between the systems as regards overall porosity when all tested cements are considered (range 2-18%), and between the cements when all tested systems are considered (range 2-17%). All test samples exceeded the required bending strength of 50 MPa, according to ISO 5833. Palaces specimens showed excessive plastic deformation in the bending test.
INTERPRETATION: There are better and worse mixing system/cement combinations for a given system and a given cement. Systems with cement collection under vacuum reduce porosity best.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15180231     DOI: 10.1080/00016470412331294415

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  4 in total

1.  Prophylactic use of antibiotic-loaded bone cement in primary total knee replacement.

Authors:  Pietro Randelli; Francesco R Evola; Paolo Cabitza; Luca Polli; Matteo Denti; Luca Vaienti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-01       Impact factor: 4.342

2.  Effect of shape on bone cement polymerization time in knee joint replacement surgery.

Authors:  Jung-Ro Yoon; Young-Rok Ko; Young-Soo Shin
Journal:  Medicine (Baltimore)       Date:  2018-04       Impact factor: 1.889

Review 3.  Role of Implantable Drug Delivery Devices with Dual Platform Capabilities in the Prevention and Treatment of Bacterial Osteomyelitis.

Authors:  Caroline Billings; David E Anderson
Journal:  Bioengineering (Basel)       Date:  2022-02-06

Review 4.  Custom-Made Antibiotic Cement Nails in Orthopaedic Trauma: Review of Outcomes, New Approaches, and Perspectives.

Authors:  Marcin K Wasko; Rafal Kaminski
Journal:  Biomed Res Int       Date:  2015-10-05       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.