Literature DB >> 15172148

Clinical and physical quality assurance for intensity modulated radiotherapy of prostate cancer.

Dirk Boehmer1, Joerg Bohsung, Ines Eichwurzel, Anne Moys, Volker Budach.   

Abstract

The implementation of intensity modulated radiotherapy (IMRT) for patients with prostate cancer in daily routine has been elaborated at our department. Our quality assurance (QA) concept is one method to pave the way for initiating IMRT treatments for starting institutions. A clinical quality assurance (CQA) procedure has been set-up for all patients before and throughout the course of radiotherapy. Simultaneously medical physicists established a physical quality assurance (PQA) concept that has been followed for all patients as well. Alternative CQA and PQA procedures are discussed. The literature is reviewed and discussed with special respect to quality assurance in IMRT of prostate cancer patients.

Entities:  

Mesh:

Year:  2004        PMID: 15172148     DOI: 10.1016/j.radonc.2004.02.016

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  9 in total

1.  Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry.

Authors:  A J Vinall; A J Williams; V E Currie; A Van Esch; D Huyskens
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

Review 2.  Some computer graphical user interfaces in radiation therapy.

Authors:  James C L Chow
Journal:  World J Radiol       Date:  2016-03-28

3.  Implementation of intensity modulated radiotherapy for prostate cancer in a private radiotherapy service in Mexico.

Authors:  María Adela Poitevin-Chacón; Gabriel Reséndiz González; Adriana Alvarado Zermeño; Jesús Manuel Flores Castro; Christian Haydée Flores Balcázar; Samuel Rosales Pérez; Miguel Angel Pérez Pastenes; Alejandro Rodríguez Laguna; Patricio Vázquez Fernández; Alejandro Calvo Fernández; Jorge Bastida Ventura
Journal:  Rep Pract Oncol Radiother       Date:  2014-12-12

4.  Statistical analysis of IMRT dosimetry quality assurance measurements for local delivery guideline.

Authors:  Jin Beom Chung; Jae Sung Kim; Sung Whan Ha; Sung-Joon Ye
Journal:  Radiat Oncol       Date:  2011-03-28       Impact factor: 3.481

5.  Eight years of IMRT quality assurance with ionization chambers and film dosimetry: experience of the Montpellier Comprehensive Cancer Center.

Authors:  Pascal Fenoglietto; Benoit Laliberté; Norbert Aillères; Olivier Riou; Jean-Bernard Dubois; David Azria
Journal:  Radiat Oncol       Date:  2011-07-20       Impact factor: 3.481

6.  Clinical Evaluation of a Two-dimensional Liquid-Filled Ion chamber Detector Array for Verification of High Modulation Small Fields in Radiotherapy.

Authors:  Miljenko Markovic; Ganesh Narayanasamy; Sotirios Stathakis; Panayiotis Mavroidis; Ines-Ana Jurkovic; Daniel Saenz; Niko Papanikolaou
Journal:  J Med Phys       Date:  2019 Apr-Jun

7.  Twin machines validation for VMAT treatments using electronic portal-imaging device: a multicenter study.

Authors:  P Fenoglietto; M Khodri; D Nguyen; F Josserand-Pietri; N Aillères
Journal:  Radiat Oncol       Date:  2016-01-14       Impact factor: 3.481

8.  SWIMRT: a graphical user interface using sliding window algorithm to construct a fluence map machine file.

Authors:  James C L Chow; Grigor N Grigorov; Nuri Yazdani
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

9.  Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator.

Authors:  Than S Kehwar; Anup K Bhardwaj; Shiv K Chakarvarti
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.