Literature DB >> 15171930

Sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry analysis of hydrochlorothiazide in rat plasma.

Takatoshi Takubo1, Hiromasa Okada, Mikio Ishii, Ken-ichi Hara, Yasuyuki Ishii.   

Abstract

A sensitive and selective method for the determination of hydrochlorothiazide (HCTZ) concentrations in rat plasma was developed using high performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-MS/MS). An aliquot of plasma (50 microl) was mixed with the solution of internal standard, hydrofluorothiazide (HFTZ), and extracted with tert-butyl methyl ether. The reconstituted extract was applied to the LC-MS/MS system with a reversed phase C8 column and eluted with distilled water/acetonitrile (85/15, v/v). To enhance negative ionization of HCTZ and HFTZ in the multiple reaction monitor (MRM), the solution consisting of acetonitlile/1% (v/v) ammonia solution (95/5, v/v) was delivered after column separation. This additional technique, so-called the post-column addition, increased sensitivity of HCTZ and HFTZ about 500- and 200-fold, respectively. The calibration curve showed good linearity (r = 0.999) over the range of 4-1000 ng/ml. Acceptable accuracy (100.8-113.1%) and precision (0.28-16.4%) were confirmed in the intra- and the inter-day analyses. It is indicated that this LC-MS/MS method is useful for pharmacokinetic studies of HCTZ in small animals, because it enabled the serial determination of plasma level of HCTZ in rats.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15171930     DOI: 10.1016/j.jchromb.2004.03.060

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Derivative and Q-analysis Spectrophotometric Methods for Estimation of Hydrochlorothiazide and Olmesartan Medoxomil in Tablets.

Authors:  K P Bhusari; P B Khedekar; Seema Dhole; V S Banode
Journal:  Indian J Pharm Sci       Date:  2009-09       Impact factor: 0.975

2.  Current literature in mass spectrometry.

Authors: 
Journal:  J Mass Spectrom       Date:  2004-11       Impact factor: 1.982

3.  Ion Pair-HPLC Method for the Simultaneous Estimation of Quinapril and Hydrochlorothiazide in Tablets.

Authors:  M Gandhimathi; T K Ravi
Journal:  Indian J Pharm Sci       Date:  2009-05       Impact factor: 0.975

4.  Simultaneous Determination and Pharmacokinetic Study of Losartan, Losartan Carboxylic Acid, Ramipril, Ramiprilat, and Hydrochlorothiazide in Rat Plasma by a Liquid Chromatography/Tandem Mass Spectrometry Method.

Authors:  Ramkumar Dubey; Manik Ghosh
Journal:  Sci Pharm       Date:  2014-11-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.