Literature DB >> 15171129

A novel robotic system for joint biomechanical tests: application to the human knee joint.

Hiromichi Fujie1, Takeshi Sekito, Akiyuki Orita.   

Abstract

The objectives of the work reported in this article were to develop a novel 6-degree-of-freedom (DOC) robotic system for knee joint biomechanics, to complete a hybrid force-position control scheme, to evaluate the system performance, and to demonstrate a combined loading test. The manipulator of the system utilizes two mechanisms; the upper mechanism has two translational axes and three rotational axes while the lower mechanism has only a single translational axis. All axes were driven with AC servo-motors. This unique configuration results in a simple kinematic description of manipulator motion. Jacobian transformation was used to calculate both the displacement and force/moment, which allowed for a hybrid control of the displacement of, and force/moment applied to, the human knee joint. The control and data acquisition were performed on a personal computer in the C-language programming environment with a multi-tasking operating system. Preliminary tests revealed that the clamp-to-clamp compliance of the system was smaller in the vertical (Z) and longitudinal (Y) directions (0.001 mm/N) than in lateral (X) direction (0.003 mm/N). The displacement error under the application of 500 N of load was smallest in the vertical direction (0.001 +/- 0.003 mm (mean +/- SD), and largest in the lateral direction (0.084 +/- 0.027 mm). Using this test system, it was possible to simulate multiple loading conditions in a human knee joint in which a cyclic anterior force was applied together with a coupled, joint compressive force, while allowing natural knee motion. The developed system seems to be a useful tool for studies of knee joint biomechanics.

Entities:  

Mesh:

Year:  2004        PMID: 15171129     DOI: 10.1115/1.1644567

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  13 in total

1.  Evaluation of knee stability with use of a robotic system.

Authors:  Savio L-Y Woo; Matthew B Fisher
Journal:  J Bone Joint Surg Am       Date:  2009-02       Impact factor: 5.284

2.  Mechanical functions of the three bundles consisting of the human anterior cruciate ligament.

Authors:  H Fujie; H Otsubo; S Fukano; T Suzuki; D Suzuki; T Mae; K Shino
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-04       Impact factor: 4.342

3.  Different effects of the lateral meniscus complete radial tear on the load distribution and transmission functions depending on the tear site.

Authors:  Tomoki Ohori; Tatsuo Mae; Konsei Shino; Hiromichi Fujie; Takehito Hirose; Yuta Tachibana; Hideki Yoshikawa; Ken Nakata
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-03-10       Impact factor: 4.342

4.  Effect of radial meniscal tear on in situ forces of meniscus and tibiofemoral relationship.

Authors:  Yuta Tachibana; Tatsuo Mae; Hiromichi Fujie; Konsei Shino; Tomoki Ohori; Hideki Yoshikawa; Ken Nakata
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-12-23       Impact factor: 4.342

5.  In Situ Joint Stiffness Increases During Skeletal Growth but Decreases Following Partial and Complete Anterior Cruciate Ligament Injury.

Authors:  Stephanie G Cone; Jorge A Piedrahita; Jeffrey T Spang; Matthew Fisher
Journal:  J Biomech Eng       Date:  2019-08-01       Impact factor: 2.097

6.  Varus-valgus instability in the anterior cruciate ligament-deficient knee: effect of posterior tibial load.

Authors:  Tomoki Ohori; Tatsuo Mae; Konsei Shino; Yuta Tachibana; Hiromichi Fujie; Hideki Yoshikawa; Ken Nakata
Journal:  J Exp Orthop       Date:  2017-06-27

7.  Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons.

Authors:  Ho-Joong Jung; Matthew B Fisher; Savio L-Y Woo
Journal:  Sports Med Arthrosc Rehabil Ther Technol       Date:  2009-05-20

8.  Evaluation of three force-position hybrid control methods for a robot-based biological joint-testing system.

Authors:  Hong-Jung Hsieh; Chih-Chung Hu; Tung-Wu Lu; Hsuan-Lun Lu; Mei-Ying Kuo; Chien-Chung Kuo; Horng-Chaung Hsu
Journal:  Biomed Eng Online       Date:  2016-06-07       Impact factor: 2.819

9.  Knee Kinematics Estimation Using Multi-Body Optimisation Embedding a Knee Joint Stiffness Matrix: A Feasibility Study.

Authors:  Vincent Richard; Giuliano Lamberto; Tung-Wu Lu; Aurelio Cappozzo; Raphaël Dumas
Journal:  PLoS One       Date:  2016-06-17       Impact factor: 3.240

10.  Effect of Calcium Phosphate-Hybridized Tendon Graft in Anatomic Single-Bundle ACL Reconstruction in Goats.

Authors:  Hirotaka Mutsuzaki; Hiromichi Fujie; Hiromi Nakajima; Makoto Fukagawa; Shunsuke Nomura; Masataka Sakane
Journal:  Orthop J Sports Med       Date:  2016-08-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.