Literature DB >> 15171123

Modal damping for monitoring bone integrity and osteoporosis.

Sofia D Panteliou1, Agathi L Xirafaki, Elias Panagiotopoulos, John N Varakis, Nikos V Vagenas, Christos G Kontoyannis.   

Abstract

We applied a noninvasive method to assess bone structural integrity. The method is based on the measurement of the dynamic characteristics of the bone (quality factor and modal damping factor) by applying vibration excitation in the range of acoustic frequencies, in the form of an acoustic sweep signal. Excised sheep femora were tested to detect changes in modal damping, density (kg/m3), bone mineral density (kg/m2) and bone mineral (hydroxyapatite) percentage. The changes were recorded after each time of chemical treatment of the bones performed to gradually cause mineral removal, thus simulating osteoporosis. It was shown that the change in quality factor and damping was in all cases on average equal or greater to the change in all other measured characteristics, thus strengthening the potential of the proposed method to become a valuable assessment tool for monitoring bone integrity and osteoporosis.

Entities:  

Mesh:

Year:  2004        PMID: 15171123     DOI: 10.1115/1.1644561

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  5 in total

1.  Dynamic bone quality: a noninvasive measure of bone's biomechanical property in osteoporosis.

Authors:  Amit Bhattacharya; Nelson B Watts; Kermit Davis; Susan Kotowski; Rakesh Shukla; Alok Kumar Dwivedi; Robert Coleman
Journal:  J Clin Densitom       Date:  2010-03-29       Impact factor: 2.617

2.  Mechanical loading, damping, and load-driven bone formation in mouse tibiae.

Authors:  Todd Dodge; Mina Wanis; Ramez Ayoub; Liming Zhao; Nelson B Watts; Amit Bhattacharya; Ozan Akkus; Alexander Robling; Hiroki Yokota
Journal:  Bone       Date:  2012-07-31       Impact factor: 4.398

3.  Detection of Meniscal Tear Effects on Tibial Vibration Using Passive Knee Sound Measurements.

Authors:  Goktug C Ozmen; Mohsen Safaei; Beren Semiz; Daniel C Whittingslow; Jennifer L Hunnicutt; Sampath Prahalad; Regina Hash; John W Xerogeanes; Omer T Inan
Journal:  IEEE Trans Biomed Eng       Date:  2021-06-17       Impact factor: 4.756

4.  Damping ratio analysis of tooth stability under various simulated degrees of vertical alveolar bone loss and different root types.

Authors:  Kuo-Ning Ho; Sheng-Yang Lee; Haw-Ming Huang
Journal:  Biomed Eng Online       Date:  2017-08-03       Impact factor: 2.819

5.  Evaluation of Femoral Bone Fracture Healing in Rats by the Modal Damping Factor and Its Correlation With Peripheral Quantitative Computed Tomography.

Authors:  Stavros Chalikias; Nikolaos Papaioannou; George Koundis; Eleni Pappa; Antonios Galanos; George Anastassopoulos; Ioannis N Sarris; Sofia Panteliou; Efstathios Chronopoulos; Ismene A Dontas
Journal:  Cureus       Date:  2021-02-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.