[Usefulness of a collecting bag for the diagnosis of post-partum hemorrhage].

G Tourné1, F Collet, P Lasnier, P Seffert.   

Abstract

OBJECTIVE: Depending on the country and the publications, post-partum hemorrhage (PPH) is either the first or second cause of maternal death in the world, including in developed countries. It remains a significant source of morbidity, severe anemia, blood transfusion, transfusion complications, acquired coagulation disorders and hemostasis hysterectomy. Visual assessment underestimates the amount of blood loss in around 45% of cases. Emergency treatment is therefore sometimes undertaken with some delay, giving time for Disseminated Intravascular Coagulation (DIC) to occur, which worsens the prognosis. A collecting plastic bag put under the pelvis of the mother just after delivery is a quantitative and objective method of measuring blood loss. The objective was to assess sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), studying correlation between bag's volume and hemoglobin and hematocrit variation.
MATERIALS AND METHODS: Included outpatients were women with unique pregnancy at term. Breech presentations were excluded. We measured serum hemoglobin and hematocrit just after admission for labor. A collecting bag, placed under the pelvis of each woman just after birth, was weighted after delivery. Serum hemoglobin and hematocrit were again assessed at three days. Post-partum hemorrhage was defined by a fall of hematocrit more than 10 points (delta Ht), or by a fall of hemoglobin more than 3g/dL (delta Hb).
RESULTS: From January 2003 to May 2003, 272 patients were included. 8.9% of the results were unuseful (n=24). The mean volume of blood loss was 190 ml (5th p=29 ml, 10th p=48 ml, 90th p=610 ml, 95th p=824 ml). The mean delta Ht was 2.7 +/- 4 pts (16.5 / -4.8). The mean delta Hb was 1.2 +/- 1.4 g/dL (5.9 / -1.5). For a delta Ht=10 the calculated bag volume was 564 ml. With this cut off we noted 5.5% PPH (n=15) prevalence=0.06. Sensitivity=34.21%. Specificity=99%. PPV=86%. NPV=90.38%. For a delta Hb=3 the calculated bag volume was 486 ml. With this cut off we noted 10.7% PPH (n=24) prevalence of PPH=0.1. Sensitivity=38.77%. Specificity=95.96%, PPV=67. 85%. NPV=87.7%.
CONCLUSION: The collecting pelvis bag is a rapid and precise procedure to diagnose PPH in the delivery room. It also enables a visual and quantitative non-subjective estimation of blood loss. Because of its simplicity and very low cost, the collecting pelvis bag should be used widely as a routine preventive measure.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15170437     DOI: 10.1016/s0368-2315(04)96443-5

Source DB:  PubMed          Journal:  J Gynecol Obstet Biol Reprod (Paris)        ISSN: 0150-9918


  6 in total

1.  Postpartum blood loss: visual estimation versus objective quantification with a novel birthing drape.

Authors:  Tripop Lertbunnaphong; Numporn Lapthanapat; Jarunee Leetheeragul; Pussara Hakularb; Amporn Ownon
Journal:  Singapore Med J       Date:  2016-06       Impact factor: 1.858

2.  Effect of a collector bag for measurement of postpartum blood loss after vaginal delivery: cluster randomised trial in 13 European countries.

Authors:  Wei-Hong Zhang; Catherine Deneux-Tharaux; Peter Brocklehurst; Edmund Juszczak; Matthew Joslin; Sophie Alexander
Journal:  BMJ       Date:  2010-02-01

3.  Measuring Post-Partum Haemorrhage in Low-Resource Settings: The Diagnostic Validity of Weighed Blood Loss versus Quantitative Changes in Hemoglobin.

Authors:  Esther Cathyln Atukunda; Godfrey Rwambuka Mugyenyi; Celestino Obua; Elly Bronney Atuhumuza; Nicholas Musinguzi; Yarine Fajardo Tornes; Amon Ganaafa Agaba; Mark Jacob Siedner
Journal:  PLoS One       Date:  2016-04-06       Impact factor: 3.240

4.  Undiagnosed abnormal postpartum blood loss: Incidence and risk factors.

Authors:  Aude Girault; Catherine Deneux-Tharaux; Loic Sentilhes; Françoise Maillard; François Goffinet
Journal:  PLoS One       Date:  2018-01-10       Impact factor: 3.240

5.  Use of a Visual Aid in addition to a Collector Bag to Evaluate Postpartum Blood loss: A Prospective Simulation Study.

Authors:  M Brooks; G Legendre; S Brun; P-E Bouet; L Pereira Mendes; B Merlot; L Sentilhes
Journal:  Sci Rep       Date:  2017-04-21       Impact factor: 4.379

6.  Measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: A prospective, randomized, case control study.

Authors:  Fang Wang; Nanjia Lu; Xiaofeng Weng; Yanping Tian; Shiwen Sun; Baohua Li
Journal:  Medicine (Baltimore)       Date:  2021-05-14       Impact factor: 1.889

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.