B K Krämer1, A Pickert, C Hohmann, H M Liebich, G A Müller, M Hablitzel, T Risler.
Abstract
The handling of low, middle and high molecular weight markers was examined in seven stable dialysis patients during hemofiltration with different membranes. Four membranes were examined in a randomized, crossover order (polysulfone, polyamide, AN69 polyacrylonitrile, Asahi polyacrylonitrile) by measuring plasma and dialysate concentrations of phosphate, creatinine, vitamin B12, beta 2-microglobulin, furanic acid, hippuric acid, retinol-binding protein, alpha-1-antitrypsin, and albumin. Sieving coefficients and plasma clearances of beta 2-microglobulin or retinol-binding protein were markedly or slightly lower during hemofiltration with the Asahi polyacrylonitrile membrane than with the other membranes (highest removal with polysulfone/AN69 polyacrylonitrile membranes). No differences of obvious clinical relevance could be seen between the four membranes. A high beta 2-microglobulin removal rate might be important to prevent dialysis-associated amyloidosis.Entities:
Mesh:
Substances:
Year: 1992 PMID: 1516991
Source DB: PubMed Journal: Int J Artif Organs ISSN: 0391-3988 Impact factor: 1.595