Literature DB >> 15167796

On-line coupling of high-performance liquid chromatography to a continuous-flow enzyme assay based on electrospray ionization mass spectrometry.

Arjen R de Boer1, Thomas Letzel, Danny A van Elswijk, Henk Lingeman, Wilfried M A Niessen, Hubertus Irth.   

Abstract

Liquid chromatography (LC) was coupled on-line to a continuous-flow enzymatic assay using electrospray ionization mass spectrometry (ESI-MS) as readout for the screening of enzyme inhibitors in complex samples. Inhibitors were detected by changes in the concentration of the enzymatic reaction products, indicating the inhibition of enzymatic activity. The molecular masses of the inhibitors were determined with high certainty by using retention time matching and peak shape comparison. Due to the high matching accuracy, baseline separation of coeluting analytes was not necessary in order to identify the correct masses of the bioactive compounds. The continuous-flow system was successfully applied for the screening of complex samples, such as natural extracts. For a red clover extract, detection limits of 0.3-0.8 micromol/L were obtained. System validation was performed by determining the IC(50) values of four inhibitors in the flow-injection mode. The IC(50) values were in the 0.11-5.6 micromol/L range and correspond closely to data obtained by microtiter plate assays. Detection limits were in the range of 0.018-0.35 micromol/L in the flow-injection mode, and 0.075-0.75 micromol/L in the LC mode. These values are well below the typical compound concentrations (1-10 micromol/L) used in high-throughput screening. Together with an interday precision of 12.6%, these results demonstrate the applicability of the system for bioactivity screening of complex mixtures, generating both chemical and biological information on bioactive compounds in a single run.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15167796     DOI: 10.1021/ac035380w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Studying enzymatic bioreactions in a millisecond microfluidic flow mixer.

Authors:  Wolfgang Buchegger; Anna Haller; Sander van den Driesche; Martin Kraft; Bernhard Lendl; Michael Vellekoop
Journal:  Biomicrofluidics       Date:  2012-03-15       Impact factor: 2.800

2.  MALDI-TOF MS as a label-free approach to rapid inhibitor screening.

Authors:  Kenneth D Greis; Songtao Zhou; Thomas M Burt; Andrew N Carr; Elizabeth Dolan; Vijayasurian Easwaran; Artem Evdokimov; Richard Kawamoto; Jeff Roesgen; Gregory F Davis
Journal:  J Am Soc Mass Spectrom       Date:  2006-04-17       Impact factor: 3.109

3.  Screening of tobacco smoke condensate for nicotinic acetylcholine receptor ligands using cellular membrane affinity chromatography columns and missing peak chromatography.

Authors:  Alexandre Maciuk; Ruin Moaddel; Jun Haginaka; Irving W Wainer
Journal:  J Pharm Biomed Anal       Date:  2007-11-26       Impact factor: 3.935

4.  A Label-free Sirtuin 1 Assay based on Droplet-Electrospray Ionization Mass Spectrometry.

Authors:  Shuwen Sun; Benjamin C Buer; E Neil G Marsh; Robert T Kennedy
Journal:  Anal Methods       Date:  2016-04-07       Impact factor: 2.896

Review 5.  Advances in mass spectrometry-based post-column bioaffinity profiling of mixtures.

Authors:  Jeroen Kool; Martin Giera; Hubertus Irth; Wilfried M A Niessen
Journal:  Anal Bioanal Chem       Date:  2010-11-24       Impact factor: 4.142

Review 6.  Development of on-line high performance liquid chromatography (HPLC)-biochemical detection methods as tools in the identification of bioactives.

Authors:  Christiaan J Malherbe; Dalene De Beer; Elizabeth Joubert
Journal:  Int J Mol Sci       Date:  2012-03-07       Impact factor: 6.208

7.  Current literature in mass spectrometry.

Authors: 
Journal:  J Mass Spectrom       Date:  2004-11       Impact factor: 1.982

8.  A Comprehensive 2D-LC/MS Online Platform for Screening of Acetylcholinesterase Inhibitors.

Authors:  Claudia Seidl; Juliana Maria de Lima; Gabriel Mazzi Leme; Ananda Ferreira Pires; Dwight R Stoll; Carmen Lúcia Cardoso
Journal:  Front Mol Biosci       Date:  2022-03-16

9.  An on-line post-column detection system for the detection of reactive-oxygen-species-producing compounds and antioxidants in mixtures.

Authors:  Jeroen Kool; Sebastiaan M Van Liempd; Stefan Harmsen; Tim Schenk; Hubertus Irth; Jan N M Commandeur; Nico P E Vermeulen
Journal:  Anal Bioanal Chem       Date:  2007-04-28       Impact factor: 4.142

10.  Reversed-phase liquid chromatography coupled on-line to estrogen receptor bioaffinity detection based on fluorescence polarization.

Authors:  Jelle Reinen; Jeroen Kool; Nico P E Vermeulen
Journal:  Anal Bioanal Chem       Date:  2008-01-31       Impact factor: 4.142

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.