Literature DB >> 15167468

In vitro study of the torsional properties of new and used ProFile nickel titanium rotary files.

Ghassan Yared1.   

Abstract

The purpose of this study was to investigate torque and angle of rotation at fracture of new and used.06 ProFile instruments. ProFile sizes 15 to 40 were tested according to American National Standards Institute/American Dental Association Specification #28. Thirty new and used instruments were tested for each size. An analysis of variance was used to compare the torque and angle of rotation at fracture between new and used instruments. The relationship between torque at fracture and size of instrument was determined with a regression analysis. The used instruments had significantly lower torque and angle of rotation at fracture values compared with the new instruments (p < 0.0001). A stronger relationship was found between the size of the instrument and the torque at fracture for the new instruments (p < 0.0001) than for the used ones (p < 0.0001). In conclusion, the repeated use of.06 ProFile instruments significantly reduced the torque and angle of rotation at fracture.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15167468     DOI: 10.1097/00004770-200406000-00008

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  8 in total

1.  The effect of electrical treatment on cyclic fatigue of NiTi instruments.

Authors:  Mohammad Ali Saghiri; Armen Asatourian; Franklin Garcia-Godoy; James L Gutmann; Mehrdad Lotfi; Nader Sheibani
Journal:  Scanning       Date:  2014-05-05       Impact factor: 1.932

2.  Fracture resistance and biomechanical behavior of different access cavities of maxillary central incisors restored with different composite resins.

Authors:  Amjad Abu Hasna; Alana Barbosa Alves Pinto; Marcelle Simões Coelho; Guilherme Schmitt de Andrade; João Paulo Mendes Tribst; Sergio Lucio Pereira de Castro Lopes; Cláudio Antonio Talge Carvalho; Alexandre Luiz Souto Borges
Journal:  Clin Oral Investig       Date:  2022-06-17       Impact factor: 3.606

3.  Nonsurgical Management of a Large Periapical Lesion Following Instrument Retrieval From the Apical Third: A Case Report With a Three-Year Follow-Up.

Authors:  Sudha Yadav; Ruchika R Nawal; Sangeeta Talwar
Journal:  Cureus       Date:  2022-05-14

4.  Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study.

Authors:  Eugenio Pedullà; Gianluca Plotino; Nicola Maria Grande; Alfio Pappalardo; Ernesto Rapisarda
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

5.  The Impact of Three Different Canal Lubricants on Fracture, Deformity and Metal Slivering of ProTaper Rotary Instruments.

Authors:  Yazdan Shantiaee; Omid Dianat; Farnoud Sharifi; Golnaz Nahvi; Golbarg Kolahi Ahari
Journal:  Iran Endod J       Date:  2014-03-08

6.  Influence of an Innovative Anti-Corrosive Solution on Resistance of Endodontic NiTi Rotary Instruments: A Preliminary Study.

Authors:  Mohammed Ali Saghiri; Armen Asatourian; Franklin Garcia Godoy; Nader Sheibani
Journal:  Eur Endod J       Date:  2017-12-21

7.  An in vitro comparison of cyclic fatigue resistance of ProTaper universal and GT series X files.

Authors:  Ramiro Montenegro-Santillán; Teresa Alegre-Domingo; Vicente Faus-Matoses; Vicente Faus-Llácer
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-05-01

8.  Stereomicroscopic evaluation of defects caused by torsional fatigue in used hand and rotary nickel-titanium instruments.

Authors:  Geeta Asthana; Marsrat I Kapadwala; Girish J Parmar
Journal:  J Conserv Dent       Date:  2016 Mar-Apr
  8 in total