| Literature DB >> 15165297 |
Abstract
Inhaled bronchodilators are routinely administered to mechanically ventilated patients to relieve dyspnea and reverse bronchoconstriction. A lower percentage of the nominal dose reaches the lower respiratory tract in a mechanically ventilated patient than in a nonintubated subject, but attention to device selection, administration technique, dosing, and patient-ventilator interface can increase lower-respiratory-tract deposition in a mechanically ventilated patient. Assessing the airway response to bronchodilator by measuring airway resistance and intrinsic positive end-expiratory pressure helps guide dosing and timing of drug delivery. Selecting the optimal aerosol-generating device for a mechanically ventilated patient requires consideration of the ease, reliability, efficacy, safety, and cost of administration. With careful attention to administration technique, bronchodilator via metered-dose inhaler or nebulizer can be safe and effective with mechanically ventilated patients.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15165297
Source DB: PubMed Journal: Respir Care ISSN: 0020-1324 Impact factor: 2.258