Literature DB >> 15163939

Effects of coil closure of patent ductus arteriosus on left anterior descending coronary artery blood flow using transthoracic Doppler echocardiography.

Kenji Harada1, Manotomo Toyono, Masamichi Tamura.   

Abstract

Transthoracic Doppler echocardiography provides noninvasive measurements of coronary blood flow in the left anterior descending coronary artery (LAD). This method has the potential to show the effects of acute changes in loading conditions on blood flow. Coil closure of patent ductus arteriosus (PDA) is a model of acute changes in blood pressure and left ventricular (LV) preload that influences coronary blood flow. We applied this technique to assess the coronary blood flow changes for patients with PDA before and immediately after PDA coil closure. We examined 9 patients (1.8 +/- 1.1 years) with simple PDA and 8 age-matched healthy children. LV dimensions and LV mass were measured. Maximum peak flow velocity and flow volume in the LAD were measured. Pulmonary to systemic flow ratios (Qp/Qs) were obtained by cardiac catheterization. After PDA coil closure, LV end-diastolic dimension decreased, and systolic and diastolic blood pressures increased significantly. The maximum peak flow velocity, LAD flow volume, and the ratio of LAD flow volume to LV mass increased significantly. The changes in maximum peak flow velocity and the ratio of LAD flow volume to LV mass (F/M) correlated positively with the changes in diastolic pressure and Qp/Qs. In 5 patients who had Qp/Qs > 1.5, the mean F/M was significantly lower compared with control subjects, but they increased to normal values after coil closure of PDA. PDA coil closure increases diastolic pressure and decreases Qp/Qs, resulting in improvement of myocardial perfusion. These findings provide new insights into the relationship between cardiac function and coronary circulation in pediatric patients with heart diseases associated with PDA.

Entities:  

Mesh:

Year:  2004        PMID: 15163939     DOI: 10.1016/j.echo.2004.02.018

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  2 in total

1.  Safety and Efficacy of the Nit-Occlud® Coil for Percutaneous Closure of Various Sizes of PDA.

Authors:  Seyong Jung; Jaehee Seol; Jaeyoung Choi; Keesoo Ha
Journal:  J Clin Med       Date:  2022-04-28       Impact factor: 4.964

2.  Myocardial ischemia following arterial switch operation: An uncommon etiology.

Authors:  R Saileela; C Shanthi; Krishna Manohar; Raghavan Subramanyan; Km Cherian
Journal:  Ann Pediatr Cardiol       Date:  2012-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.