Pump-induced haemolysis: a comparison of short-term ventricular assist devices.

M Bennett1, S Horton, C Thuys, S Augustin, M Rosenberg, C Brizard.   

Abstract

Centrifugal pumps are superior to roller pumps for extended support durations in terms of pump-induced haemolysis. In this study, we evaluated the commonly used Biomedicus BP 50 and compared it with the Jostra Rotaflow and a standard roller pump in an in vitro test circuit. Each circuit was run for a six-day period and repeated five times. Plasma haemoglobin values showed the roller pump to become more haemolytic than the Biomedicus (p = 0.022) and the Rotaflow. A statistically significant difference between the Biomedicus and the Rotaflow was observed on day six of the trial (p = 0.016), with the Rotaflow showing lower levels of haemolysis than the Biomedicus. These results support the use of the new generation centrifugal pump, the Rotaflow, as a suitable device for short-term ventricular assist.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15162925     DOI: 10.1191/0267659104pf729oa

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  5 in total

1.  Retrieval of critically ill adults using extracorporeal membrane oxygenation: an Australian experience.

Authors:  P Forrest; J Ratchford; B Burns; R Herkes; A Jackson; B Plunkett; P Torzillo; P Nair; E Granger; M Wilson; R Pye
Journal:  Intensive Care Med       Date:  2011-02-26       Impact factor: 17.440

2.  Plasma Free Hemoglobin Is an Independent Predictor of Mortality among Patients on Extracorporeal Membrane Oxygenation Support.

Authors:  Hesham R Omar; Mehdi Mirsaeidi; Stephanie Socias; Collin Sprenker; Christiano Caldeira; Enrico M Camporesi; Devanand Mangar
Journal:  PLoS One       Date:  2015-04-22       Impact factor: 3.240

3.  Analysis of Haematological and Biochemical Blood Parameters After Electrical Cardioversion of Atrial Fibrillation in Dogs.

Authors:  Agnieszka Noszczyk-Nowak; Marcin Michałek; Adrian Janiszewski; Agnieszka Kurosad; Agnieszka Sławuta; Alicja Cepiel; Urszula Pasławska
Journal:  J Vet Res       Date:  2018-03-30       Impact factor: 1.744

4.  Haemolysis induced by mechanical circulatory support devices: unsolved problems.

Authors:  Inge Köhne
Journal:  Perfusion       Date:  2020-06-23       Impact factor: 1.972

Review 5.  The Roles of Membrane Technology in Artificial Organs: Current Challenges and Perspectives.

Authors:  Bao Tran Duy Nguyen; Hai Yen Nguyen Thi; Bich Phuong Nguyen Thi; Dong-Ku Kang; Jeong F Kim
Journal:  Membranes (Basel)       Date:  2021-03-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.