Literature DB >> 15157252

Analysis of ABO discrepancies occurring in 35 French hospitals.

J Chiaroni1, D Legrand, I Dettori, V Ferrera.   

Abstract

BACKGROUND: The risk of immunohemolytic reaction owing to ABO-mismatched mistransfusion is 100 to 1000 times higher than the risk of viral infection. Like analysis of incident reports, evaluation of near-miss events can provide useful insight into hazardous situations for mis-matched blood transfusion. The aim of this prospective study was to assess the incidence and root causes of all ABO discrepancies, detected by a central hematology laboratory, in blood samples referred from 35 district hospitals. STUDY DESIGN AND METHODS: ABO discrepancies were detected by comparing either two current blood specimens or a current and historical specimen collected over a 5-year study period. Discrepancies were investigated by retyping new samples, checking sample identification, and reviewing previous hospital records.
RESULTS: A total of 118 ABO discrepancies were discovered in a series of 407,769 tests carried out during the study period. The incidence of ABO discrepancies was 1 per 3,400. This figure was 10 times higher than the incidence of ABO-mismatched transfusions. Most of these ABO discrepancies were due to phlebotomy errors, that is, collection from wrong patient. The second most common cause involved clerical errors during patient registration or identification.
CONCLUSION: ABO discrepancies can result from errors made not only by the medical staff during phlebotomy but also to by the clerical staff during registration and identification. These findings emphasize the need to standardize data transmission between health care personnel.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15157252     DOI: 10.1111/j.1537-2995.2004.03337.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  8 in total

1.  Comparison of gel column, card, and cartridge techniques for dog erythrocyte antigen 1.1 blood typing.

Authors:  Mayank Seth; Karen V Jackson; Sarah Winzelberg; Urs Giger
Journal:  Am J Vet Res       Date:  2012-02       Impact factor: 1.156

2.  Comparison of five blood-typing methods for the feline AB blood group system.

Authors:  Mayank Seth; Karen V Jackson; Urs Giger
Journal:  Am J Vet Res       Date:  2011-02       Impact factor: 1.156

3.  Acute Transfusion Reactions (ATRs) in Intensive Care Unit (ICU): A Retrospective Study.

Authors:  Rajesh Kumar; Manvi Gupta; Varun Gupta; Amarjit Kaur; Sonia Gupta
Journal:  J Clin Diagn Res       Date:  2014-02-03

4.  Use of an identification system based on biometric data for patients requiring transfusions guarantees transfusion safety and traceability.

Authors:  Francesco Bennardello; Carmelo Fidone; Sergio Cabibbo; Salvatore Calabrese; Giovanni Garozzo; Grazia Cassarino; Agostino Antolino; Giuseppe Tavolino; Nuccio Zisa; Cadigia Falla; Giuseppe Drago; Giovanna Di Stefano; Pietro Bonomo
Journal:  Blood Transfus       Date:  2009-07       Impact factor: 3.443

5.  Blood loss control with two doses of tranexamic Acid in a multimodal protocol for total knee arthroplasty.

Authors:  Miguel Ortega-Andreu; Hanna Pérez-Chrzanowska; Reyes Figueredo; Enrique Gómez-Barrena
Journal:  Open Orthop J       Date:  2011-03-16

6.  A Case of Transfusion Error in a Trauma Patient With Subsequent Root Cause Analysis Leading to Institutional Change.

Authors:  Sean Patrick Clifford; Paul Brian Mick; Brian Matthew Derhake
Journal:  J Investig Med High Impact Case Rep       Date:  2016-05-05

7.  Analysis of Blood Group Discrepancy in Healthy Blood Donors at a Tertiary Care Referral Hospital from Eastern India: A Retrospective Study.

Authors:  Ansuman Sahu; Satya Prakash; Niladri Das; Suman Sudha Routray; Archana Naik; Somnath Mukherjee
Journal:  J Lab Physicians       Date:  2022-02-09

8.  Blood Group Discrepancies at a Regional Blood Center.

Authors:  Hayedeh Javadzadeh Shahshahani; Azam Hayati
Journal:  Int J Hematol Oncol Stem Cell Res       Date:  2020-01-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.