Literature DB >> 15156105

Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses.

X Q Hu1, G H Isaac, J Fisher.   

Abstract

In metal on metal hip prostheses, the contact mechanics can influence the lubrication and wear rate. In particular, during the bedding-in wear, the contact area gradually increases to an optimal value, and the wear rate reduces as the contact stress reduces and the lubrication conditions improve. Geometrical designs that reduce the volume of bedding-in wear as the optimal contact area develops are preferable. The objective of this study was to analyse the wear volume as a function of contact area during the bedding-in period, with the aim of identifying geometrical design configurations that give lower bedding-in wear. As the radial clearance was reduced, the bedding-in wear volume to reach an optimal contact area also reduced. For a fixed radial clearance, increasing the head diameter also reduced the bedding-in wear volume. Copryright 2004 IOS Press

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15156105

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  5 in total

1.  Does diametrical clearance influence the wear of Pinnacle hip implants?

Authors:  Sean Bergiers; Harry Hothi; Johann Henckel; Antti Eskelinen; John Skinner; Alister Hart
Journal:  Bone Joint Res       Date:  2020-08-25       Impact factor: 5.853

2.  Retroacetabular osteolytic lesions behind well-fixed prosthetic cups: pilot study of bearings-retaining surgery.

Authors:  Luca Pierannunzii; Florian Fischer; Marco d'Imporzano
Journal:  J Orthop Traumatol       Date:  2008-10-25

3.  (v) Simulation and measurement of wear in metal-on-metal bearings in vitro- understanding the reasons for increased wear.

Authors:  John Fisher; Mazen Al Hajjar; Sophie Williams; Joanne Tipper; Eileen Ingham; Louise Jennings
Journal:  Orthop Trauma       Date:  2012-08

4.  Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions.

Authors:  Mazen Al-Hajjar; John Fisher; Sophie Williams; Joanne L Tipper; Louise M Jennings
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-12-20       Impact factor: 3.368

5.  Does bearing size influence metal ion levels in large-head metal-on-metal total hip arthroplasty? A comparison of three total hip systems.

Authors:  James Smith; David Lee; Kamal Bali; Pam Railton; David Kinniburgh; Peter Faris; Deborah Marshall; Brian Burkart; James Powell
Journal:  J Orthop Surg Res       Date:  2014-01-28       Impact factor: 2.359

  5 in total