Literature DB >> 15155310

The impact of heparin-coated cardiopulmonary bypass circuits on pulmonary function and the release of inflammatory mediators.

R de Vroege1, W van Oeveren, J van Klarenbosch, W Stooker, M A J M Huybregts, C E Hack, L van Barneveld, L Eijsman, C R H Wildevuur.   

Abstract

UNLABELLED: Reduction of the inflammatory reaction with the use of heparin coating has been found during and after cardiopulmonary bypass (CPB). The question remains whether this reduced reaction also decreases the magnitude of CPB-induced pulmonary dysfunction. We therefore evaluated the effects of a heparin-coated circuit versus a similar uncoated circuit on pulmonary indices as well as on inflammatory markers of complement activation (C3b/c), elastase-alpha(1)-antitrypsin complex, and secretory phospholipase A(2) (sPLA(2)) during and after CPB. Fifty-one patients were randomly assigned into two groups undergoing coronary artery bypass grafting with either a heparin-coated (Group 1) or an uncoated (Group 2) circuit. During CPB, a continuous positive airway pressure of 5 cm H(2)O and a fraction of inspired oxygen (FIO(2)) of 0.21 were maintained. Differences in favor of the coated circuit were found in pulmonary shunt fraction (P < 0.05), pulmonary vascular resistance index (P < 0.05), and PaO(2)/FIO(2) ratio (P < 0.05) after CPB and in the intensive care unit. During and after CPB, the coated group demonstrated lower levels of sPLA(2). After CPB, C3b/c and the elastase-alpha(1)-antitrypsin complex were significantly less in the coated group (P < 0.001). The coated circuit was associated with a reduced inflammatory response, decreased pulmonary vascular resistance index and pulmonary shunt fraction, and increased PaO(2)/FIO(2) ratio, suggesting that the coated circuit may have beneficial effects on pulmonary function. The correlation with sPLA(2), leukocyte activation, and postoperative leukocyte count suggests reduced activation of pulmonary capillary endothelial cells. IMPLICATIONS: Heparin coating of the extracorporeal circuit reduces the inflammatory response during cardiopulmonary bypass. Analysis of indices of pulmonary function indicates that use of heparin coating may result in less impaired gas exchange.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15155310     DOI: 10.1213/01.ane.0000114551.64123.79

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  7 in total

1.  Evaluation of biocompatible cardiopulmonary bypass circuit use during pediatric open heart surgery.

Authors:  Joseph Deptula; Kimberly Glogowski; Kellie Merrigan; Kim Hanson; Donald Felix; James Hammel; Kim Duncan
Journal:  J Extra Corpor Technol       Date:  2006-03

Review 2.  Attenuating the Systemic Inflammatory Response to Adult Cardiopulmonary Bypass: A Critical Review of the Evidence Base.

Authors:  R Clive Landis; Jeremiah R Brown; David Fitzgerald; Donald S Likosky; Linda Shore-Lesserson; Robert A Baker; John W Hammon
Journal:  J Extra Corpor Technol       Date:  2014-09

3.  Changes in cysteinyl leukotrienes during and after cardiac surgery with cardiopulmonary bypass in patients with and without chronic obstructive pulmonary disease.

Authors:  Nicolas de Prost; Claudine El-Karak; Maria Avila; Fumito Ichinose; Marcos F Vidal Melo
Journal:  J Thorac Cardiovasc Surg       Date:  2011-03-05       Impact factor: 5.209

Review 4.  Anti-Inflammatory Effects of Heparin and Its Derivatives: A Systematic Review.

Authors:  Sarah Mousavi; Mandana Moradi; Tina Khorshidahmad; Maryam Motamedi
Journal:  Adv Pharmacol Sci       Date:  2015-05-12

5.  Nebulized heparin and salbutamol versus salbutamol alone in acute exacerbations of chronic obstructive pulmonary disease requiring mechanical ventilation: a double-blind randomized controlled trial.

Authors:  Tarek Mohamed Ashoor; Ahmad Mahmoud Hasseb; Ibrahim Mamdouh Esmat
Journal:  Korean J Anesthesiol       Date:  2020-02-28

Review 6.  Strategies to prevent intraoperative lung injury during cardiopulmonary bypass.

Authors:  Efstratios E Apostolakis; Efstratios N Koletsis; Nikolaos G Baikoussis; Stavros N Siminelakis; Georgios S Papadopoulos
Journal:  J Cardiothorac Surg       Date:  2010-01-11       Impact factor: 1.637

Review 7.  Control of Blood Coagulation by Hemocompatible Material Surfaces-A Review.

Authors:  Janna Kuchinka; Christian Willems; Dmitry V Telyshev; Thomas Groth
Journal:  Bioengineering (Basel)       Date:  2021-12-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.