Literature DB >> 15152691

The effect of Monte Carlo statistical uncertainties on the evaluation of dose distributions in radiation treatment planning.

I Kawrakow1.   

Abstract

This paper discusses the effect of statistical uncertainties present in Monte Carlo (MC) calculated dose distributions on the evaluation of a 'cost function' that expresses the suitability of a treatment plan for the intended treatment. The mathematical derivations given are valid for any 'well-behaved' cost function. The validity of the general expressions is demonstrated using numerical examples. It is shown that random dose uncertainties lead to statistical and systematic uncertainties on the cost function. The balance between the two types of uncertainty and the desired accuracy on the cost function presents a clear criterion for the maximum acceptable MC dose uncertainties. It is demonstrated that it is possible to remove the systematic cost function uncertainty. Finally, it is shown that when the dose distribution is close to a true optimum, MC calculations of the cost function converge to the true result as one over the number of particles simulated, i.e. much faster than the individual dose uncertainties.

Mesh:

Year:  2004        PMID: 15152691     DOI: 10.1088/0031-9155/49/8/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  The effect of statistical noise on IMRT plan quality and convergence for MC-based and MC-correction-based optimized treatment plans.

Authors:  Jeffrey V Siebers
Journal:  J Phys Conf Ser       Date:  2008-04-04

2.  Dosimetric impact of statistical uncertainty on Monte Carlo dose calculation algorithm in volumetric modulated arc therapy using Monaco TPS for three different clinical cases.

Authors:  Mohandass Palanisamy; Khanna David; Manigandan Durai; Narendra Bhalla; Abhishek Puri
Journal:  Rep Pract Oncol Radiother       Date:  2019-02-18

3.  Maintaining dosimetric quality when switching to a Monte Carlo dose engine for head and neck volumetric-modulated arc therapy planning.

Authors:  Vladimir Feygelman; Kujtim Latifi; Mark Bowers; Kevin Greco; Eduardo G Moros; Max Isacson; Agnes Angerud; Jimmy Caudell
Journal:  J Appl Clin Med Phys       Date:  2022-02-25       Impact factor: 2.243

4.  Calculation of excess dose to the eye phantom due to a distanced shielding for electron therapy in head and neck cancers.

Authors:  Keyvan Jabbari; Mahnaz Roayaei; Hosein Saberi
Journal:  J Med Signals Sens       Date:  2012-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.