Literature DB >> 15152159

Transcatheter closure of secundum atrial septal defects with complex anatomy.

Carlos A C Pedra1, Simone R F Pedra, César A Esteves, Renata Cassar, Sérgio C Pontes, Sérgio L N Braga, Valmir F Fontes.   

Abstract

The aim of this study was to evaluate the feasibility, safety and efficacy of transcatheter closure of secundum atrial septal defects (ASD) in patients with complex anatomy. From September 1997 to July 2003, a total of 40 patients (median age, 34 years; 65% female) with complex ASDs, defined as the presence of a large defect (stretched diameter >26 mm) associated with a deficient rim (n=23); multiple defects (n=8); a multi-fenestrated septum (n=5); and defects associated with an aneurysmal septum irrespective of their size (n=4) underwent closure. The Helex device was used in 4 patients and the Amplatzer in the remaining. Two devices were implanted in 2 patients each. Implantation was unsuccessful in 5 patients, with 4 having large defects associated with a deficient anterior rim and a floppy posterior septum. Occlusion was observed in 22 of 35 patients (63%) immediately after implantation and in 31 (89%) at a mean follow-up of 18+/-9 months. No major complications occurred. Right ventricular end-diastolic dimensions (indexed for body surface area) decreased from 135+/-25% before closure to 124+/-15% 24 hours after closure, and to 92+/-12% after 12 months. Two patients with 2 distant defects and 2 patients with large defects remained with shunts (<4 mm) at the latest visit. Transcatheter closure of complex secundum ASDs was feasible, safe and effective; however, large defects associated with a deficient anterior rim and a floppy posterior septum may not be suitable for this approach.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15152159

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  9 in total

1.  Transthoracic echocardiographic guidance during transcatheter closure of atrial septal defects in children and adults.

Authors:  Abdullah Erdem; Turkay Sarıtas; Cenap Zeybek; Ilker Kemal Yucel; Nurdan Erol; Halil Demır; Ender Odemıs; Yalim Yalcın; Ahmet Celebı
Journal:  Int J Cardiovasc Imaging       Date:  2011-08-11       Impact factor: 2.357

2.  Transcatheter closure of atrial septal defects improves right ventricular volume, mass, function, pulmonary pressure, and functional class: a magnetic resonance imaging study.

Authors:  S P Schoen; T Kittner; S Bohl; M U Braun; G Simonis; A Schmeisser; R H Strasser
Journal:  Heart       Date:  2005-11-11       Impact factor: 5.994

3.  First experience with the 2005 modified Gore Helex ASD occluder system.

Authors:  R Kozlik-Feldmann; R Dalla Pozza; U Römer; T Rampp; P Bernasconi; S Däbritz; H Netz
Journal:  Clin Res Cardiol       Date:  2006-07-20       Impact factor: 5.460

4.  Percutaneous retrieval and redeployment of an atrial septal occluder under three-dimensional transesophageal echocardiographic guidance: a case report.

Authors:  Jinhee Ahn; Jin Hee Kim; Jung Hyun Choi; Jun-Hyok Oh
Journal:  J Korean Med Sci       Date:  2014-05-30       Impact factor: 2.153

5.  Should transcatheter closure of atrial septal defects with inferior-posterior deficient rim still be attempted?

Authors:  Pascal Amedro; Selin Bayburt; Anass Assaidi; Bernard Kreitmann; Gilbert Habib; Virginie Fouilloux; Alain Fraisse
Journal:  J Thorac Dis       Date:  2019-03       Impact factor: 2.895

6.  Short-term outcomes of transcatheter closure of secundum atrial septal defect in children and adolescents: An experience of two centers in Upper Egypt.

Authors:  Safaa H Ali; Amal El Sisi; Duaa M Raafat; Salah-Eldin Amry; Sharaf E D Mahamoud
Journal:  J Saudi Heart Assoc       Date:  2017-05-10

7.  Catheter-based closure of a large atrial septal defect with inferior rim deficiency using pulmonary vein slide-out assisted implantation technique: a case report.

Authors:  Salvatore Evola; Oreste Fabio Triolo; Giuseppina Novo; Eustaquio Maria Onorato
Journal:  Eur Heart J Case Rep       Date:  2021-02-08

Review 8.  Role of Echocardiography in the Diagnosis and Interventional Management of Atrial Septal Defects.

Authors:  P Syamasundar Rao
Journal:  Diagnostics (Basel)       Date:  2022-06-18

9.  Safety of Occlutech Septal Occluder ACCELL Flex II for Transcatheter Closure of Secundum Atrial Septal Defects in Children: A Long-Term Follow-Up.

Authors:  Amal M El-Sisi; Sonia A El-Saiedi; Rasha Ammar; Asmaa Abdelhameed; Ziyad M Hijazi; Mohammed M Soliman
Journal:  J Interv Cardiol       Date:  2022-01-04       Impact factor: 2.279

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.