BACKGROUND: Peripherally inserted central catheters (PICC) have been used extensively as a cost-effective and safe form of medium-term intravascular access. There are only limited data about complications of PICC lines in oncology patients despite theoretical concerns about the higher risks of complications in these patients as a result of cancer itself and cancer therapy. AIMS: To document the frequency and type of PICC complications in patients with solid tumours. METHODS: All patients with solid tumours who were treated at Flinders Medical Centre, Adelaide, South Australia, Australia between January 2000 and March 2001 were included in a retrospective review of PICC complications. RESULTS: Twenty-seven PICC lines were inserted in 17 patients; 40.7% (11/27) of PICC lines developed complications requiring early removal of the PICC. Complications encountered were sepsis (systemic and cellulitis), thrombosis, blockage and leakage. Septic complications were found at a rate of 8/1000 PICC days or 25.7% (7/27) of PICC inserted. The median dwell time was 20 days. The mean time for a complication to occur was 27.5 days. CONCLUSIONS: The present study demonstrates a high rate of complications, which is higher than the complication rates reported in studies of non-oncology patients. PICC lines should be used with caution in patients with solid tumours. Prospective studies of the factors influencing the incidence of complications might be warranted.
BACKGROUND: Peripherally inserted central catheters (PICC) have been used extensively as a cost-effective and safe form of medium-term intravascular access. There are only limited data about complications of PICC lines in oncology patients despite theoretical concerns about the higher risks of complications in these patients as a result of cancer itself and cancer therapy. AIMS: To document the frequency and type of PICC complications in patients with solid tumours. METHODS: All patients with solid tumours who were treated at Flinders Medical Centre, Adelaide, South Australia, Australia between January 2000 and March 2001 were included in a retrospective review of PICC complications. RESULTS: Twenty-seven PICC lines were inserted in 17 patients; 40.7% (11/27) of PICC lines developed complications requiring early removal of the PICC. Complications encountered were sepsis (systemic and cellulitis), thrombosis, blockage and leakage. Septic complications were found at a rate of 8/1000 PICC days or 25.7% (7/27) of PICC inserted. The median dwell time was 20 days. The mean time for a complication to occur was 27.5 days. CONCLUSIONS: The present study demonstrates a high rate of complications, which is higher than the complication rates reported in studies of non-oncology patients. PICC lines should be used with caution in patients with solid tumours. Prospective studies of the factors influencing the incidence of complications might be warranted.
Authors: L Lefebvre; E Noyon; D Georgescu; V Proust; C Alexandru; M Leheurteur; J C Thery; L Savary; O Rigal; F Di Fiore; C Veyret; F Clatot Journal: Support Care Cancer Date: 2015-09-05 Impact factor: 3.603
Authors: Susan R Kahn; Wendy Lim; Andrew S Dunn; Mary Cushman; Francesco Dentali; Elie A Akl; Deborah J Cook; Alex A Balekian; Russell C Klein; Hoang Le; Sam Schulman; M Hassan Murad Journal: Chest Date: 2012-02 Impact factor: 9.410