Literature DB >> 15150068

Laparoscopic placement of hepatic artery infusion pumps: technical considerations and early results.

Jun Cheng1, Dennis Hong, Guojing Zhu, Lee L Swanstrom, Paul D Hansen.   

Abstract

BACKGROUND: Laparoscopic hepatic artery infusion pump (LHAIP) placement is a novel treatment option for patients with colorectal liver metastases. This study investigates technical difficulties with regard to variant hepatic arteries and the preliminary outcomes for patients treated with LHAIP placement.
METHODS: Between March 1998 and January 2003, 38 patients with colorectal metastases confined to the liver, 35 (92%) of who had prior systemic chemotherapy that failed, were treated with LHAIP.
RESULTS: Twelve patients (32%) had LHAIP placement only, and 26 (68%) had pump placement combined with laparoscopic radiofrequency ablation (LRFA; 24 patients) and/or liver resection (2 patients). Variant hepatic arterial (HA) anatomy was present in 18 patients (47%). The presence of a variant HA did not increase pump complications, operative time, or blood loss (P >/=.20) or decrease the functional time of pump use (P =.91) in comparison with normal anatomy. In all patients with a variant HA, laparoscopic ligation of the variant vessel and/or cannulation of nongastroduodenal artery resulted in complete hepatic perfusion. Three misperfusions identified intraoperatively with use of methylene blue injection were corrected by laparoscopic ligation (two) or postoperative angioembolization (one). Postoperative pump radionuclide flow studies confirmed isolated hepatic artery infusion in all cases. There was a 13% pump-related complication rate. During a median follow-up of 11 months (0.5 to 35.5 months), the actuarial rate of overall survival was 47% and the estimated median survival time was 17.5 months.
CONCLUSIONS: LHAIP placement is technically feasible, and variant HA is not associated with increased pump complications or decreased pump functional time.

Entities:  

Mesh:

Year:  2004        PMID: 15150068     DOI: 10.1245/ASO.2004.05.013

Source DB:  PubMed          Journal:  Ann Surg Oncol        ISSN: 1068-9265            Impact factor:   5.344


  4 in total

1.  Robotic-assisted placement of a hepatic artery infusion catheter for regional chemotherapy.

Authors:  Minia Hellan; Alessio Pigazzi
Journal:  Surg Endosc       Date:  2007-08-18       Impact factor: 4.584

2.  Hepatic arterial infusion pump chemotherapy in the management of colorectal liver metastases: expert consensus statement.

Authors:  P J Karanicolas; P Metrakos; K Chan; T Asmis; E Chen; T P Kingham; N Kemeny; G Porter; R C Fields; J Pingpank; E Dixon; A Wei; S Cleary; G Zogopoulos; C Dey; M D'Angelica; Y Fong; S Dowden; Y J Ko
Journal:  Curr Oncol       Date:  2014-02       Impact factor: 3.677

3.  Robotic hepatic arterial infusion pump placement.

Authors:  Motaz Qadan; Michael I D'Angelica; Nancy E Kemeny; Andrea Cercek; T Peter Kingham
Journal:  HPB (Oxford)       Date:  2017-01-26       Impact factor: 3.647

4.  Laparoscopic intraarterial catheterization with selective ICG fluorescence imaging in colorectal surgery.

Authors:  Christian Heiliger; Jerzy Piecuch; Alexander Frank; Dorian Andrade; Viktor von Ehrlich-Treuenstätt; Dobromira Evtimova; Florian Kühn; Jens Werner; Konrad Karcz
Journal:  Sci Rep       Date:  2021-07-20       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.