Literature DB >> 15150031

Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors: biomechanical evaluation of new meniscus refixation systems.

Thore Zantop1, Ann Katleen Eggers, Andre Weimann, Joachim Hassenpflug, Wolf Petersen.   

Abstract

BACKGROUND: The newest generation of meniscus repair devices is designed to combine the benefits of the all-inside technique with the biomechanical properties of sutures. HYPOTHESIS: New flexible all-inside suture anchors have better fixation strength than rigid anchors, but there is no difference when compared to conventional horizontal and vertical mattress sutures. STUDY
DESIGN: Controlled laboratory study.
METHODS: In fresh-frozen bovine menisci, initial fixation strength, stiffness, and failure mode of different meniscus fixation techniques (FastT-Fix, RapidLoc, Meniscus Arrow, horizontal and vertical 2.0 Ethibond sutures) were evaluated in a computer-based materials testing machine at a rate of 12.5 mm/sec.
RESULTS: The vertical and horizontal FastT-Fix suture anchors were the strongest devices with regard to pullout strength, with no significant difference compared to the vertical 2-0 Ethibond sutures. Horizontal sutures, Meniscus Arrow, and RapidLoc had significantly lower pullout strength. Vertical and horizontal FastT-Fix suture anchors showed significantly higher stiffness than the other devices.
CONCLUSIONS: Biomechanical properties of flexible all-inside meniscus anchors (FastT-Fix) are comparable to conventional vertical suture techniques. Characteristics of the flexible RapidLoc are comparable to rigid anchors (Meniscus Arrow). CLINICAL RELEVANCE: From the biomechanical point of view, flexible all-inside meniscus refixation devices are an alternative to conventional suture techniques and rigid meniscus anchors.

Entities:  

Mesh:

Year:  2004        PMID: 15150031     DOI: 10.1177/0363546503260749

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  9 in total

Review 1.  All-inside meniscal repair using the FasT-Fix meniscal repair system: is still needed to avoid weight bearing? A systematic review.

Authors:  Alberto Vascellari; Enrico Rebuzzi; Stefano Schiavetti; Nicolò Coletti
Journal:  Musculoskelet Surg       Date:  2012-07-07

2.  Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears.

Authors:  Matthias J Feucht; Eduardo Grande; Johannes Brunhuber; Nikolaus Rosenstiel; Rainer Burgkart; Andreas B Imhoff; Sepp Braun
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-03       Impact factor: 4.342

3.  The concept of three-dimensional hold of both circumferential and radial collagen fibres of the meniscus.

Authors:  Ashraf Abdelkafy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-12       Impact factor: 4.342

4.  The effect of inclination angle on the strength of vertical mattress configuration for meniscus repair.

Authors:  Mehmet Erduran; Onur Hapa; Baran Şen; Yavuz Kocabey; Diler Erdemli; Mehran Aksel; Hasan Havitçioğlu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-09       Impact factor: 4.342

Review 5.  Meta-analysis on biomechanical properties of meniscus repairs: are devices better than sutures?

Authors:  Daniel M Buckland; Patrick Sadoghi; Matthias D Wimmer; Patrick Vavken; Geert I Pagenstert; Victor Valderrabano; Claudio Rosso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-20       Impact factor: 4.342

6.  Tensile strength of the pullout repair technique for the medial meniscus posterior root tear: a porcine study.

Authors:  Masataka Fujii; Takayuki Furumatsu; Haowei Xue; Shinichi Miyazawa; Yuya Kodama; Tomohito Hino; Yusuke Kamatsuki; Toshifumi Ozaki
Journal:  Int Orthop       Date:  2017-07-14       Impact factor: 3.075

7.  Determination of the safe penetration depth during all-inside meniscal repair of the posterior part of the lateral meniscus using the FasT-Fix suture repair system.

Authors:  Mohamed Mahmoud Abouheif; Hayatoshi Shibuya; Takuya Niimoto; Wirat Kongcharoensombat; Masataka Deie; Nobuo Adachi; Mitsuo Ochi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-06       Impact factor: 4.342

8.  All-inside suture device is superior to meniscal arrows in meniscal repair: a prospective randomized multicenter clinical trial with 2-year follow-up.

Authors:  Nina Jullum Kise; Jon Olav Drogset; Arne Ekeland; Einar Andreas Sivertsen; Stig Heir
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-11-09       Impact factor: 4.342

9.  Increased Construct Stiffness With Meniscal Repair Sutures and Devices Increases the Risk of Cheese-Wiring During Biomechanical Load-to-Failure Testing.

Authors:  Sebastian Müller; Tanja Schwenk; Michael de Wild; Dimitris Dimitriou; Claudio Rosso
Journal:  Orthop J Sports Med       Date:  2021-06-15
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.