Literature DB >> 15147155

Influence of blood collection in plastic vs. glass evacuated serum-separator tubes on hormone and tumour marker levels.

Eva M L Smets1, Josien E Dijkstra-Lagemaat, Marinus A Blankenstein.   

Abstract

Introduction of preanalytical automation in our laboratory required the use of plastic blood collection tubes. Because of possible interference caused by adsorption of components to the plastic wall and because there is virtually no literature on this subject, we investigated the influence of collection of serum in plastic tubes on the results of nearly all our immunoassays for hormones and tumour markers. Blood from healthy volunteers was collected simultaneously in glass and plastic tubes, or sera prepared from blood collected in glass tubes were brought into the plastic tubes under investigation. Hormone and tumour marker levels were measured in the pairs thus obtained. Results were analysed using paired t-tests or Wilcoxon signed rank tests. We found small but statistically significant differences (p<0.05) between glass and plastic for free triiodothyronine, progesterone, prolactin, prostate-specific antigen and pregnancy-associated plasma protein-A. Non-significant trends (0.05<p<0.15) were seen with alpha-foetoprotein, androstenedione, BR (an assay for carbohydrate antigen 15.3), human chorionic gonadotropin and testosterone. Passing and Bablok regression analysis, however, revealed no clinically relevant differences (slopes ranged from 0.89 for progesterone to 1.07 for pregnancy-associated plasma protein-A, while intercepts were all small). We concluded that a switch to plastic blood collection tubes could occur without any implications for the interpretation of results.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15147155     DOI: 10.1515/CCLM.2004.076

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  6 in total

1.  Effect of various anticoagulants on the bioanalysis of drugs in rat blood: implication for pharmacokinetic studies of anticancer drugs.

Authors:  Preeti Kulkarni; Ashwin Karanam; Murari Gurjar; Sagar Dhoble; Arvind B Naik; Bhaskar H Vidhun; Vikram Gota
Journal:  Springerplus       Date:  2016-12-20

2.  A comparative study on the effect of blood collection tubes on stress oxidative markers.

Authors:  Alireza Bastin; Saba Fooladi; Amir Hossein Doustimotlagh; Sina Vakili; Amir Hashem Aminizadeh; Sanaz Faramarz; Hamidreza Shiri; Mohammad Hadi Nematollahi
Journal:  PLoS One       Date:  2022-04-06       Impact factor: 3.240

3.  Head-to-Head Comparison of Different Blood Collecting Tubes for Quantification of Alzheimer's Disease Biomarkers in Plasma.

Authors:  Lijun Jiang; Xulong Ding; Wenxiao Wang; Xiaobin Yang; Tao Li; Peng Lei
Journal:  Biomolecules       Date:  2022-08-28

4.  The effects of substituting glassware for plasticware and the use of an ethanol vector on oocyte maturation in vitro.

Authors:  A D Macaulay; C K Hamilton; P M Bartlewski; W A King
Journal:  Vet Med Int       Date:  2012-03-14

Review 5.  The validity of androgen assays.

Authors:  Malcolm Carruthers; Tom R Trinick; Michael J Wheeler
Journal:  Aging Male       Date:  2007-09       Impact factor: 5.892

Review 6.  Interferences from blood collection tube components on clinical chemistry assays.

Authors:  Raffick A R Bowen; Alan T Remaley
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.