Literature DB >> 15145590

Establishment of HPC(R2A) for regrowth control in non-chlorinated distribution systems.

Wolfgang Uhl1, Gabriela Schaule.   

Abstract

Drinking water distributed without disinfection and without regrowth problems for many years may show bacterial regrowth when the residence time and/or temperature in the distribution system increases or when substrate and/or bacterial concentration in the treated water increases. An example of a regrowth event in a major German city is discussed. Regrowth of HPC bacteria occurred unexpectedly at the end of a very hot summer. No pathogenic or potentially pathogenic bacteria were identified. Increased residence times in the distribution system and temperatures up to 25 degrees C were identified as most probable causes and the regrowth event was successfully overcome by changing flow regimes and decreasing residence times. Standard plate counts of HPC bacteria using the spread plate technique on nutrient rich agar according to German Drinking Water Regulations (GDWR) had proven to be a very good indicator of hygienically safe drinking water and to demonstrate the effectiveness of water treatment. However, the method proved insensitive for early regrowth detection. Regrowth experiments in the lab and sampling of the distribution system during two summers showed that spread plate counts on nutrient-poor R2A agar after 7-day incubation yielded 100 to 200 times higher counts. Counts on R2A after 3-day incubation were three times less than after 7 days. As the precision of plate count methods is very poor for counts less than 10 cfu/plate, a method yielding higher counts is better suited to detect upcoming regrowth than a method yielding low counts. It is shown that for the identification of regrowth events HPC(R2A) gives a further margin of about 2 weeks for reaction before HPC(GDWR). Copyright 2003 Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15145590     DOI: 10.1016/j.ijfoodmicro.2003.08.010

Source DB:  PubMed          Journal:  Int J Food Microbiol        ISSN: 0168-1605            Impact factor:   5.277


  4 in total

Review 1.  Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges.

Authors:  Emmanuelle I Prest; Frederik Hammes; Mark C M van Loosdrecht; Johannes S Vrouwenvelder
Journal:  Front Microbiol       Date:  2016-02-01       Impact factor: 5.640

2.  Flow cytometry total cell counts: a field study assessing microbiological water quality and growth in unchlorinated drinking water distribution systems.

Authors:  G Liu; E J Van der Mark; J Q J C Verberk; J C Van Dijk
Journal:  Biomed Res Int       Date:  2013-06-02       Impact factor: 3.411

3.  Enumeration of heterotrophic bacteria in water for dialysis: Comparison of the efficiency of reasoner'2 agar and plate count agar.

Authors:  Adriana Bugno; Adriana Aparecida Buzzo Almodóvar; Tatiana Caldas Pereira
Journal:  Braz J Microbiol       Date:  2010-03-01       Impact factor: 2.476

4.  Bacterial characterization of Beijing drinking water by flow cytometry and MiSeq sequencing of the 16S rRNA gene.

Authors:  Tingting Liu; Weiwen Kong; Nan Chen; Jing Zhu; Jingqi Wang; Xiaoqing He; Yi Jin
Journal:  Ecol Evol       Date:  2016-01-18       Impact factor: 2.912

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.