Literature DB >> 15145589

Heterotrophic plate count methodology in the United States.

Donald J Reasoner1.   

Abstract

In the United States (US), the history of bacterial plate counting (BPC) methods used for water can be traced largely through Standard Methods for the Examination of Water and Wastewater (Standard Methods). The bacterial count method has evolved from the original Standard Methods (1st edition, 1905) plate count which used nutrient gelatin and incubation at 20 degrees C for 48 h, to the HPC method options in the latest edition of Standard Methods that provide greater flexibility of application, depending on the data needs of the water analyst. The use of agar-agar as a gelling agent, replacing gelatin, allowed the use of higher incubation temperatures and resulted in the "body temperature count" (37 degrees C) found in the 3rd through the 8th edition of Standard Methods. The change from 37 degrees C incubation to 35+/-0.5 degrees C accommodated laboratories that did both milk and water analyses. By using a single temperature, fewer incubators were needed. The term "standard plate count" (SPC) first appeared in 1960 (11th edition) along with plate count agar. Incubation at 20 degrees C for the plate count was dropped from the 13th to 15th editions and few changes were made in the SPC method from the 11th edition through the 13th editions. Plate count analysis of bottled waters was included in the 14th edition (1975), calling for incubation at 35+/-0.5 degrees C for 72+/-4 h. Perhaps the most significant changes in plate count methods occurred with the 16th edition (1985). The term heterotrophic plate count replaced the standard plate count, and the spread plate (SP) and membrane filter (MF) methods were added along with new media for pour and spread plates (R2A agar and NWRI agar, both low nutrient) and for the membrane filter method (mHPC medium). The use of low nutrient media, lower incubation temperature, and longer incubation times, results in higher plate count results for most water samples. The options currently available, including low and high nutrient media, incubation temperatures (20 degrees C, 28 degrees C or 35 degrees C), plating methods (pour plate (PP), spread plate and membrane filter) and range of incubation times (24, 48, 72 h and 5-7 days) provide great flexibility in the application of the HPC analysis to drinking water.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15145589     DOI: 10.1016/j.ijfoodmicro.2003.08.008

Source DB:  PubMed          Journal:  Int J Food Microbiol        ISSN: 0168-1605            Impact factor:   5.277


  18 in total

Review 1.  Heterotrophic bacteria in drinking water distribution system: a review.

Authors:  Shakhawat Chowdhury
Journal:  Environ Monit Assess       Date:  2011-11-11       Impact factor: 2.513

2.  Protein Extraction by Means of Electroporation from E. coli with Preserved Viability.

Authors:  Sasa Haberl Meglic; Tilen Marolt; Damijan Miklavcic
Journal:  J Membr Biol       Date:  2015-07-23       Impact factor: 1.843

3.  A comparison of 2 laboratory methods to test dental unit waterline water quality.

Authors:  Nuala Porteous; Yuyu Sun; Shichien Dang; John Schoolfield
Journal:  Diagn Microbiol Infect Dis       Date:  2013-09-17       Impact factor: 2.803

4.  Comparison of alkaline lysis with electroextraction and optimization of electric pulses to extract plasmid DNA from Escherichia coli.

Authors:  Saša Haberl; Marko Jarc; Aleš Strancar; Matjaž Peterka; Duša Hodžić; Damijan Miklavčič
Journal:  J Membr Biol       Date:  2013-07-06       Impact factor: 1.843

5.  Evaluation of 3 dental unit waterline contamination testing methods.

Authors:  Nuala Porteous; Yuyu Sun; John Schoolfield
Journal:  Gen Dent       Date:  2015 Jan-Feb

6.  Assessment of Bacterial Transfer From Patient to Chiropractor During Spinal Manipulation.

Authors:  Fariha Amod; Feroz M Swalaha; Poovendhree Reddy
Journal:  J Chiropr Med       Date:  2021-10-26

7.  Combination of microsecond and nanosecond pulsed electric field treatments for inactivation of Escherichia coli in water samples.

Authors:  Maj Kobe Žgalin; Duša Hodžić; Matej Reberšek; Maša Kandušer
Journal:  J Membr Biol       Date:  2012-08-03       Impact factor: 1.843

8.  Characterization of biofilm formation on a humic material.

Authors:  A L Rodrigues; A G Brito; P Janknecht; J Silva; A V Machado; R Nogueira
Journal:  J Ind Microbiol Biotechnol       Date:  2008-08-20       Impact factor: 3.346

9.  Proposal for a method to estimate nutrient shock effects in bacteria.

Authors:  Nuno F Azevedo; Sofia M Bragança; Lúcia C Simões; Laura Cerqueira; Carina Almeida; Charles W Keevil; Maria J Vieira
Journal:  BMC Res Notes       Date:  2012-08-08

10.  Enumeration of heterotrophic bacteria in water for dialysis: Comparison of the efficiency of reasoner'2 agar and plate count agar.

Authors:  Adriana Bugno; Adriana Aparecida Buzzo Almodóvar; Tatiana Caldas Pereira
Journal:  Braz J Microbiol       Date:  2010-03-01       Impact factor: 2.476

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.