Literature DB >> 15144300

Measurement of cardiac output by transpulmonary arterial thermodilution using a long radial artery catheter. A comparison with intermittent pulmonary artery thermodilution.

R M L'e Orme1, D W Pigott, F G Mihm.   

Abstract

Cardiac output can be measured accurately by transpulmonary arterial thermodilution using the PiCCO (Pulsion Medical Systems, Munich, Germany) system with a femoral artery catheter. We have investigated the accuracy of a new 50 cm 4 French gauge radial artery catheter and the ability to use the system with a shorter radial catheter. We studied 18 patients who had undergone coronary artery surgery and made three simultaneous measurements of cardiac output by arterial thermodilution and with a pulmonary artery catheter. The radial catheter was withdrawn in 5 cm increments and the measurements were repeated. We found close agreement between arterial thermodilution and pulmonary artery thermodilution with a mean (SD) bias of 0.38 (0.77) l x min(-1). Arterial thermodilution became unreliable once the catheter had been withdrawn by more than 5 cm. We conclude that cardiac output measurement with arterial thermodilution with a radial catheter is interchangeable with that derived from a pulmonary artery catheter, and that a centrally sited arterial catheter is required for accurate determination of cardiac output by transpulmonary arterial thermodilution.

Entities:  

Mesh:

Year:  2004        PMID: 15144300     DOI: 10.1111/j.1365-2044.2004.03710.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  7 in total

1.  Organ dysfunction during sepsis.

Authors:  Suveer Singh; Timothy W Evans
Journal:  Intensive Care Med       Date:  2006-02-11       Impact factor: 17.440

2.  Accuracy and precision of transcardiopulmonary thermodilution in patients with cardiogenic shock.

Authors:  Bonaventura Schmid; Katrin Fink; Manfred Olschewski; Stephan Richter; Tilmann Schwab; Michael Brunner; Hans-Joerg Busch
Journal:  J Clin Monit Comput       Date:  2015-10-01       Impact factor: 2.502

3.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

4.  Stroke volume determination using transcardiopulmonary thermodilution and arterial pulse contour analysis in severe aortic valve disease.

Authors:  Martin Petzoldt; Carsten Riedel; Jan Braeunig; Sebastian Haas; Matthias S Goepfert; Hendrik Treede; Stephan Baldus; Alwin E Goetz; Daniel A Reuter
Journal:  Intensive Care Med       Date:  2013-01-04       Impact factor: 17.440

5.  Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients.

Authors:  Nikolai M Krivitski; Victor V Kislukhin; Naveen V Thuramalla
Journal:  Pediatr Crit Care Med       Date:  2008-07       Impact factor: 3.624

6.  Late evaluation of upper limb arterial flow in patients after long radial (PiCCO™) catheter placement.

Authors:  Lucas Rovira; Gerardo Aguilar; Alberto Cuñat; Francisco J Belda
Journal:  Ann Intensive Care       Date:  2015-01-16       Impact factor: 6.925

7.  Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial.

Authors:  William T McGee; Jeffrey L Horswell; Joachim Calderon; Gerard Janvier; Tom Van Severen; Greet Van den Berghe; Lori Kozikowski
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

  7 in total