Microflow NMR: concepts and capabilities.

Dean L Olson1, James A Norcross, Mark O'Neil-Johnson, Paul F Molitor, David J Detlefsen, Aaron G Wilson, Timothy L Peck.   

Abstract

The principles and parameters to consider when choosing an NMR probe for analysis of a volume- or mass-limited sample are identified and discussed. In particular, a capillary-based microflow probe is described which has a mass sensitivity comparable to cryoprobes (observe volume approximately 40 microL), but with several distinct advantages. The microflow probe has a flowcell volume of 5 microL and an observe volume of 1.5 microL and is equipped with proton and carbon observe channels, deuterium lock, and z-gradient capability. The entire flow path is fused silica; inlet and outlet capillary inner diameters are 50 microm to minimize sample dispersion, making it well-suited to volume-limited samples. An injected sample of 1 nmol of sucrose (0.34 microg in 3 microL, 0.33 mM; MW = 342 g/mol) yields a 1D proton spectrum in 10 min on a spectrometer of 500 MHz or higher. In another example, 15 microg of sucrose (in 3 microL; 15 mM, 45 nmol) is injected and parked in the probe to yield a heteronuclear multiple-quantum coherence (HMQC) spectrum in less than 15 h. The natural product muristerone A (75 microg in 3 microL, 50 mM, 150 nmol; MW = 497 g/mol) was delivered to the flow cell, and a gradient correlation spectroscopy spectrum was acquired in 7 min, a gradient HMQC in 4 h, and a gradient heteronuclear multiple-bond correlation in 11 h. Four basic modes of sample injection into the probe vary in degree of user intervention, speed, solvent consumption, and sample delivery efficiency. Manual, manual-assisted (employing a micropump), automated (using an autosampler), and capillary HPLC modes of operation are described.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15144211     DOI: 10.1021/ac035426l

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  21 in total

1.  Nuclear magnetic resonance at the picomole level of a DNA adduct.

Authors:  Roger Kautz; Poguang Wang; Roger W Giese
Journal:  Chem Res Toxicol       Date:  2013-10-08       Impact factor: 3.739

2.  Tissue targeted metabonomics: metabolic profiling by microdialysis sampling and microcoil NMR.

Authors:  Kristin E Price; Shannon S Vandaveer; Craig E Lunte; Cynthia K Larive
Journal:  J Pharm Biomed Anal       Date:  2005-08-10       Impact factor: 3.935

Review 3.  Biomarkers for neuroAIDS: the widening scope of metabolomics.

Authors:  Gurudutt Pendyala; Elizabeth J Want; William Webb; Gary Siuzdak; Howard S Fox
Journal:  J Neuroimmune Pharmacol       Date:  2006-10-10       Impact factor: 4.147

4.  Magnetic microparticle aggregation for viscosity determination by MR.

Authors:  Rui Hong; Michael J Cima; Ralph Weissleder; Lee Josephson
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

5.  The application of micro-coil NMR probe technology to metabolomics of urine and serum.

Authors:  John H Grimes; Thomas M O'Connell
Journal:  J Biomol NMR       Date:  2011-03-06       Impact factor: 2.835

6.  Multiplexed NMR: an automated CapNMR dual-sample probe.

Authors:  James A Norcross; Craig T Milling; Dean L Olson; Duanxiang Xu; Anthony Audrieth; Robert Albrecht; Ke Ruan; John Likos; Claude Jones; Timothy L Peck
Journal:  Anal Chem       Date:  2010-09-01       Impact factor: 6.986

7.  New Solenoidal Microcoil NMR Probe Using Zero-Susceptibility Wire.

Authors:  Ravi Kc; Ian D Henry; Gregory H J Park; Al Aghdasi; Daniel Raftery
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2010-02-17       Impact factor: 1.176

8.  Automated microflow NMR: routine analysis of five-microliter samples.

Authors:  Ariane Jansma; Tiffany Chuan; Robert W Albrecht; Dean L Olson; Timothy L Peck; Bernhard H Geierstanger
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

9.  Saturation transfer double-difference NMR spectroscopy using a dual solenoid microcoil difference probe.

Authors:  Scott J Bergeron; Ian D Henry; Robert E Santini; Abdollah Aghdasi; Daniel Raftery
Journal:  Magn Reson Chem       Date:  2008-10       Impact factor: 2.447

10.  Design and construction of a versatile dual volume heteronuclear double resonance microcoil NMR probe.

Authors:  Ravi Kc; Ian D Henry; Gregory H J Park; Daniel Raftery
Journal:  J Magn Reson       Date:  2008-12-25       Impact factor: 2.229