Literature DB >> 15144204

Single-drop microextraction combined with low-temperature electrothermal vaporization ICPMS for the determination of trace Be, Co, Pd, and Cd in biological samples.

Linbo Xia1, Bin Hu, Zucheng Jiang, Yunli Wu, Yu Liang.   

Abstract

A new method of single-drop microextraction combined with low-temperature electrothermal vaporization (LTETV)-ICPMS was proposed for the determination of trace Be, Co, Pd, and Cd with benzoylacetone (BZA) as both extractant and chemical modifier. Several factors that influence the microextraction efficiency, such as sample flow rate, microdrop volume, and extraction time, were investigated and the optimized microextraction conditions were established. Be, Co, Pd, and Cd in the postextraction organic phase were directly determined by LTETV-ICPMS with the use of BZA as chemical modifier. The chemical modification of BZA in LTETV-ICPMS was studied, and the factors affecting the formation of chelates and vaporization/transportation of chelates were investigated. Under the optimized conditions, the detection limits of the method were 0.12, 0.99, 1.5, and 0.27 pg/mL for Be, Co, Pd, and Cd, and the relative standard deviations for 0.1 ng/mL Be, Co, Pd, and Cd were 16, 14, 14, and 11%, respectively. After 10 min of extraction, the enrichment factors were 160 (Be), 125 (Co), 40 (Pd), and 180 (Cd). The proposed method was applied to the determination of trace Be, Co, Pd, and Cd in biological reference materials, and the determined values were in good agreement with the certified values.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15144204     DOI: 10.1021/ac035437e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Methods of liquid phase microextraction for the determination of cadmium in environmental samples.

Authors:  Analú Pires Santos; Maria das Graças Andrade Korn; Valfredo Azevedo Lemos
Journal:  Environ Monit Assess       Date:  2017-08-09       Impact factor: 2.513

2.  Simultaneous derivatization and extraction of nitrophenols in soil and rain samples using modified hollow-fiber liquid-phase microextraction followed by gas chromatography-mass spectrometry.

Authors:  Hamid Reza Sobhi; Ali Esrafili; Hadi Farahani; Mitra Gholami; Mohammad Mehdi Baneshi
Journal:  Environ Monit Assess       Date:  2013-05-07       Impact factor: 2.513

3.  Beryllium in urine by ICP-MS: a comparison of low level exposed workers and unexposed persons.

Authors:  Jackie Morton; Elizabeth Leese; Richard Cotton; Nicholas Warren; John Cocker
Journal:  Int Arch Occup Environ Health       Date:  2010-10-21       Impact factor: 3.015

4.  Spectroscopic analysis of bosentan in biological samples after a liquid-liquid microextraction.

Authors:  Sanaz Sajedi-Amin; Karim Assadpour-Zeynali; Vahid Panahi-Azar; Abbas Kebriaeezadeh; Maryam Khoubnasabjafari; Khalil Ansarin; Vahid Jouyban-Gharamaleki; Abolghasem Jouyban
Journal:  Bioimpacts       Date:  2015-12-27

Review 5.  Green Approaches to Sample Preparation Based on Extraction Techniques.

Authors:  Alshymaa A Aly; Tadeusz Górecki
Journal:  Molecules       Date:  2020-04-09       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.