Literature DB >> 15142610

Comparison between the surface plasmon resonance (SPR) and the quartz crystal microbalance (QCM) method in a structural analysis of human endothelin-1.

Leopoldo Laricchia-Robbio1, Roberto P Revoltella.   

Abstract

In this study, an automated surface plasmon resonance (SPR)-based biosensor was compared with a quartz crystal microbalance (QCM) biosensor. The two biosensor systems were used for characterizing a site-directed monoclonal antibody (mAb), raised against the C-terminal heptapeptide ET-1(15-21) of the human endothelin (ET-1). The mAb was characterized by its capacity for binding to ET-1, ET-3, Big.ET-1(22-38), the C-terminal (ET-1(15-21), ET-1(16-21), ET-1(17-21)), and six derivates of ET-1(16-21), each containing a substitution with alanine (Ala) of a single aminoacid from position 16-21, respectively. The mAb reacted well with ET-1 and its fragments ET-1(15-21), ET-1(16-21), ET-1(17-21), but showed only a partial cross-reaction with ET-3, and did not bind human Big.ET-1(22-38). The Ala substitution on position 16,17, or 19 of ET-1(16-21) did not affect the antibody binding capacity of the hexapaptide ET-1(16-21). On the contrary, Ala substitution or Asp(18), Ile(20) and particularly Trp(21), inhibited its immunoreactivity. Thus the C-terminal represents an immunodominant epitope in ET-1 and is important for antibody binding. The SPR and QCM response signals were similar in shape but differing in time scales, reflecting differences in detection mechanisms. With regard to the fundamental problem of comparing different measurement principles, we found a good correlation between results obtained using the BIA technology and the QCM.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15142610     DOI: 10.1016/j.bios.2003.11.026

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Concanavalin A-polysaccharides binding affinity analysis using a quartz crystal microbalance.

Authors:  Fohona S Coulibaly; Bi-Botti C Youan
Journal:  Biosens Bioelectron       Date:  2014-03-31       Impact factor: 10.618

Review 2.  In Vitro Analytical Approaches to Study Plant Ligand-Receptor Interactions.

Authors:  Pedro Jimenez Sandoval; Julia Santiago
Journal:  Plant Physiol       Date:  2020-02-07       Impact factor: 8.340

3.  Rapid development of new protein biosensors utilizing peptides obtained via phage display.

Authors:  Jun Wu; Jong Pil Park; Kevin Dooley; Donald M Cropek; Alan C West; Scott Banta
Journal:  PLoS One       Date:  2011-10-07       Impact factor: 3.240

4.  Comparison of a Resonant Mirror Biosensor (IAsys) and a Quartz Crystal Microbalance (QCM) for the Study on Interaction between Paeoniae Radix 801 and Endothelin-1.

Authors:  Jiadong Huang; Qing Lin; Jinghua Yu; Shenguang Ge; Jing Li; Min Yu; Zixia Zhao; Xinsheng Wang; Xiuming Zhang; Xiaorui He; Liang Yuan; Huijun Yin; Tetsuo Osa; Keji Chen; Qiang Chen
Journal:  Sensors (Basel)       Date:  2008-12-15       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.