Literature DB >> 15142572

Urea biosensor based on PANi(urease)-Nafion/Au composite electrode.

Yung-Chien Luo1, Jing-Shan Do.   

Abstract

The polyaniline (PANi)-Nafion composite film was prepared onto the ceramic plate by the cyclic voltammetry (CV) method with the various cycle numbers. When the PANi-Nafion/Au/ceramic plate with the preparing cycle number of 5 was as working electrode, the cathodic peak current was achieved as 84.0 microA in 60 mg dl(-1) NH4Cl buffer solution. On the other hand, the small cathodic peak currents for buffer solution in the presence of 60 mg dl(-1) LiOH, NaCl and KCl, respectively, were found with the same composite electrode as working electrode. The cathodic peak current decreased from 84.0 to 16.3 microA in the 60 mg dl(-1) NH4Cl buffer solution when the cycle number for preparing PANi-Nafion/Au/ceramic plate composite electrode with the CV method increased from 5 to 15. The enzyme of urease was immobilized onto the PANi-Nafion/Au/ceramic plate composite film by the electrochemical immobilization and the casting methods and used as sensing electrode to detect the concentration of urea in the buffer solution. The sensitivity of composite electrode immobilized with the casting method was greater than that of electrochemical immobilization method. The sensitivity and the detecting limit of the urea sensor were found to be 0.7 and 5.27 microA (mg dl(-1))(-1)cm(-2), as well as 6 and 0.3 mg dl(-1), respectively, when urease was immobilized by glutaraldehyde (GA) cross-linker and Nafion network, respectively.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15142572     DOI: 10.1016/j.bios.2003.11.028

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  14 in total

1.  Use of Water Soluble and Phosphorescent MPA-capped CdTe Quantum Dots for the Detection of Urea.

Authors:  Tülay Oymak; Nusret Ertaş; Uğur Tamer
Journal:  Turk J Pharm Sci       Date:  2018-04-02

2.  Ion-sensitive field-effect transistor for biological sensing.

Authors:  Chang-Soo Lee; Sang Kyu Kim; Moonil Kim
Journal:  Sensors (Basel)       Date:  2009-09-07       Impact factor: 3.576

3.  Immobilization of HRP in Mesoporous Silica and Its Application for the Construction of Polyaniline Modified Hydrogen Peroxide Biosensor.

Authors:  Chien-Chung Chen; Jing-Shan Do; Yesong Gu
Journal:  Sensors (Basel)       Date:  2009-06-12       Impact factor: 3.576

4.  Preparation of a porous composite film for the fabrication of a hydrogen peroxide sensor.

Authors:  Mu-Yi Hua; Chun-Jen Chen; Hsiao-Chien Chen; Rung-Ywan Tsai; Wen Cheng; Chun-Lin Cheng; Yin-Chih Liu
Journal:  Sensors (Basel)       Date:  2011-05-31       Impact factor: 3.576

5.  A biosensor for urea from succinimide-modified acrylic microspheres based on reflectance transduction.

Authors:  Alizar Ulianas; Lee Yook Heng; Musa Ahmad
Journal:  Sensors (Basel)       Date:  2011-08-26       Impact factor: 3.576

6.  Eliminating the Interference of Oxygen for Sensing Hydrogen Peroxide with the Polyaniline Modified Electrode.

Authors:  Yesong Gu; Chien-Chung Chen
Journal:  Sensors (Basel)       Date:  2008-12-12       Impact factor: 3.576

7.  Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite.

Authors:  Gautam Das; Hyon Hee Yoon
Journal:  Int J Nanomedicine       Date:  2015-08-25

8.  In situ preparation of monodispersed Ag/polyaniline/Fe3O4 nanoparticles via heterogeneous nucleation.

Authors:  Longchun Bian; Lixia Bao; Jiliang Wang; Jingxin Lei
Journal:  Nanoscale Res Lett       Date:  2013-07-03       Impact factor: 4.703

9.  A simple visual ethanol biosensor based on alcohol oxidase immobilized onto polyaniline film for halal verification of fermented beverage samples.

Authors:  Bambang Kuswandi; Titi Irmawati; Moch Amrun Hidayat; Musa Ahmad
Journal:  Sensors (Basel)       Date:  2014-01-27       Impact factor: 3.576

10.  pH Sensitivity of Novel PANI/PVB/PS3 Composite Films.

Authors:  Edric Gill; Arousian Arshak; Khalil Arshak; Olga Korostynska
Journal:  Sensors (Basel)       Date:  2007-12-19       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.