Literature DB >> 15141712

Intravascular ultrasound imaging for detection of pseudoaneurysm with aortobronchopulmonary fistula after graft replacement of descending aorta.

Takeshiro Fujii1, Yoshinori Watanabe, Noritsugu Shiono, Muneyasu Kawasaki, Katsunori Yoshihara, Nobuya Koyama.   

Abstract

A 63-year-old man had undergone graft replacement of the descending aorta due to dissection of aortic aneurysm nine years before and closure of an aortobronchopulmonary fistula two years before. He was admitted to our hospital because of massive hemoptysis. Angiography and chest computed tomography (CT) revealed a pseudoaneurysm on the proximal end caused by graft detachment. Intravascular ultrasound clearly revealed half round detachment on both ends of the graft. Replacement of the ascending, arch and distal aorta including the graft was performed, and the patient's postoperative course has been satisfactory. We have concluded that intravascular ultrasound is a useful method for detecting pseudoaneurysm after graft replacement which is not evident on cineangiography, CT or distal subtraction angiography.

Entities:  

Mesh:

Year:  2004        PMID: 15141712     DOI: 10.1007/s11748-004-0110-3

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  5 in total

1.  Evaluation of acute aortic dissection by intravascular ultrasonography.

Authors:  A R Weintraub; S L Schwartz; N G Pandian; S E Katz; O J Kwon; V Millan; R Bojar
Journal:  N Engl J Med       Date:  1990-11-29       Impact factor: 91.245

2.  Intravascular ultrasound for diagnosis of aortic dissection.

Authors:  A Pande; B Meier; M Fleisch; R Kammerlander; F Simonet; R Lerch
Journal:  Am J Cardiol       Date:  1991-03-15       Impact factor: 2.778

3.  Restenosis of endovascular stents from stent compression.

Authors:  K Rosenfield; R Schainfeld; A Pieczek; L Haley; J M Isner
Journal:  J Am Coll Cardiol       Date:  1997-02       Impact factor: 24.094

4.  Balloon angioplasty of coarctation of the aorta evaluated with intravascular ultrasound imaging.

Authors:  J K Harrison; K H Sheikh; C J Davidson; K B Kisslo; M E Leithe; S I Himmelstein; R J Kanter; T M Bashore
Journal:  J Am Coll Cardiol       Date:  1990-03-15       Impact factor: 24.094

5.  The use of endovascular techniques for the treatment of complications of aortic dissection.

Authors:  P J Walker; M D Dake; R S Mitchell; D C Miller
Journal:  J Vasc Surg       Date:  1993-12       Impact factor: 4.268