A 3D computer graphics approach to brachytherapy planning.

Frank Weichert1, Martin Wawro, Carsten Wilke.   

Abstract

Intravascular brachytherapy (IVB) can significantly reduce the risk of restenosis after interventional treatment of stenotic arteries, if planned and applied correctly. In order to facilitate computer-based IVB planning, a three-dimensional reconstruction of the stenotic artery based on intravascular ultrasound (IVUS) sequences is desirable. For this purpose, the frames of the IVUS sequence are properly aligned in space, possible gaps inbetween the IVUS frames are filled by interpolation with radial basis functions known from scattered data interpolation. The alignment procedure uses additional information which is obtained from biplane X-ray angiography performed simultaneously during the capturing of the IVUS sequence. After IVUS images and biplane angiography data are acquired from the patient, the vessel-wall borders and the IVUS catheter are detected by an active contour algorithm. Next, the twist (relative orientation) between adjacent IVUS frames is determined by a sequential triangulation method. The absolute orientation of each frame is established by a stochastic analysis based on anatomical landmarks. Finally, the reconstructed 3D vessel model is visualized by methods of combined volume and polygon rendering. The reconstruction is then used for the computation of the radiation-distribution within the tissue, emitted from a beta-radiation source. All these steps are performed during the percutaneous intervention.

Entities:  

Mesh:

Year:  2004        PMID: 15139531     DOI: 10.1023/b:caim.0000021858.04849.cb

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  5 in total

1.  Reporting vascular brachytherapy: proposal for a revision of the AAPM TG 60 report. American Association of Physicists in Medicine.

Authors:  U Quast
Journal:  Cardiovasc Radiat Med       Date:  1999 Oct-Dec

2.  Three-dimensional segmentation of luminal and adventitial borders in serial intravascular ultrasound images.

Authors:  R Shekhar; R M Cothren; D G Vince; S Chandra; J D Thomas; J F Cornhill
Journal:  Comput Med Imaging Graph       Date:  1999 Nov-Dec       Impact factor: 4.790

3.  Monte Carlo dose calculations of beta-emitting sources for intravascular brachytherapy: a comparison between EGS4, EGSnrc, and MCNP.

Authors:  R Wang; X A Li
Journal:  Med Phys       Date:  2001-02       Impact factor: 4.071

4.  Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound.

Authors:  G P Prause; S C DeJong; C R McKay; M Sonka
Journal:  Int J Card Imaging       Date:  1997-12

5.  Three-dimensional reconstruction of moving arterial beds from digital subtraction angiography.

Authors:  D L Parker; D L Pope; R Van Bree; H W Marshall
Journal:  Comput Biomed Res       Date:  1987-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.