Literature DB >> 15138903

Injection pressures by anesthesiologists during simulated peripheral nerve block.

Richard Claudio1, Admir Hadzic, Henry Shih, Jerry D Vloka, Jose Castro, Zbigniew Koscielniak-Nielsen, Daniel M Thys, Alan C Santos.   

Abstract

BACKGROUND AND OBJECTIVES: Anesthesiologists typically rely on a subjective evaluation ("syringe feel") of possible abnormal resistance to injection while performing a peripheral nerve block (PNB). A greater force required to perform the injection is believed to be associated with intraneural injection. The hypothesis of this study is that anesthesiologists vary in their perception of "normal" injection force, that the syringe feel method is inconsistent in estimating resistance, and that needle design may affect the injection force.
METHODS: Thirty anesthesiologists were asked to inject a local anesthetic, as they would in their everyday practice, through a commonly used syringe and needle assembly. Injection force was measured using an in-line manometer coupled to a computer via an analog-to-digital conversion board. In addition, injection force at clinically relevant injection speeds was determined using 3 differently sized needles from 4 different manufacturers.
RESULTS: During a steady injection rate, all anesthesiologists perceived an increase in the force required to inject, even with minor pressures changes (0.6 +/- 0.3 psi). However, the 30 anesthesiologists, 21 (70%) initiated injection using a force that resulted in pressures greater than 20 psi; 15 (50%) used a force greater than 25 psi, and 3 (10%) exerted pressures greater than 30 psi. Pressures varied as much as 20-fold among needles of the same gauge/length from different manufacturers (P <.01).
CONCLUSIONS: Anesthesiologists vary widely in their perception of appropriate force and rate of injection during PNB. The syringe-feel method of assessing injection force is inconsistent and may be further affected by variability in needle design.

Entities:  

Mesh:

Year:  2004        PMID: 15138903     DOI: 10.1016/j.rapm.2003.12.013

Source DB:  PubMed          Journal:  Reg Anesth Pain Med        ISSN: 1098-7339            Impact factor:   6.288


  11 in total

Review 1.  Peripheral nerve blocks for perioperative management of patients having orthopedic surgery or trauma of the lower extremity.

Authors:  Takashige Iwata; Sundaram Lakshman; Alpana Singh; Marina Yufa; Rich Claudio; Admir Hadzić
Journal:  Bosn J Basic Med Sci       Date:  2005-05       Impact factor: 3.363

Review 2.  Upper extremity regional anesthesia: essentials of our current understanding, 2008.

Authors:  Joseph M Neal; J C Gerancher; James R Hebl; Brian M Ilfeld; Colin J L McCartney; Carlo D Franco; Quinn H Hogan
Journal:  Reg Anesth Pain Med       Date:  2009 Mar-Apr       Impact factor: 6.288

3.  Injection pressure as a marker of intraneural injection in procedures of peripheral nerves blockade.

Authors:  Ilvana Vucković; Faruk Dilberović; Amela Kulenović; Kucuk-Alija Divanović; Alma Voljevica; Eldan Kapur
Journal:  Bosn J Basic Med Sci       Date:  2006-11       Impact factor: 3.363

4.  Injection pressure monitoring: no more excuses.

Authors:  Jeff Gadsden
Journal:  J Clin Monit Comput       Date:  2015-06-12       Impact factor: 2.502

5.  An improvised pressure gauge for regional nerve blockade/anesthesia injections: an initial study.

Authors:  Jayaprakash Patil; Hari Ankireddy; Antony Wilkes; David Williams; Michael Lim
Journal:  J Clin Monit Comput       Date:  2015-05-05       Impact factor: 2.502

6.  Detection of neurovascular structures using injection pressure in blockade of brachial plexus in rat.

Authors:  Ilvana Vucković; Admir Hadzić; Faruk Dilberović; Amela Kulenović; Zakira Mornjaković; Irfan Zulić; Kucuk-Alija Divanović; Eldan Kapur; Esad Cosović; Alma Voljevica
Journal:  Bosn J Basic Med Sci       Date:  2005-08       Impact factor: 3.363

7.  Pressure Monitoring of Intraneural an Perineural Injections Into the Median, Radial, and Ulnar Nerves; Lessons From a Cadaveric Study.

Authors:  Andrzej Krol; Matthew Szarko; Arber Vala; Jose De Andres
Journal:  Anesth Pain Med       Date:  2015-06-22

8.  Performance accuracy of hand-on-needle versus hand-on-syringe technique for ultrasound-guided regional anesthesia simulation for emergency medicine residents.

Authors:  Brian Johnson; Andrew Herring; Michael Stone; Arun Nagdev
Journal:  West J Emerg Med       Date:  2014-09

9.  Lumbar plexus block for management of hip surgeries.

Authors:  Hamid Reza Amiri; Mohammad Mahdi Zamani; Saeid Safari
Journal:  Anesth Pain Med       Date:  2014-07-08

10.  Neurotoxicity of perineural vs intraneural-extrafascicular injection of liposomal bupivacaine in the porcine model of sciatic nerve block.

Authors:  M Damjanovska; E Cvetko; A Hadzic; A Seliskar; T Plavec; K Mis; I Vuckovic Hasanbegovic; T Stopar Pintaric
Journal:  Anaesthesia       Date:  2015-09-04       Impact factor: 6.955