New bioimpedance analysis system: improved phenotyping with whole-body analysis.

A Pietrobelli1, F Rubiano, M-P St-Onge, S B Heymsfield.   

Abstract

OBJECTIVE: Bioimpedance analysis (BIA) is a potential field and clinical method for evaluating skeletal muscle mass (SM) and %fat. A new BIA system has 8-(two on each hand and foot) rather than 4-contact electrodes allowing for rapid 'whole-body' and regional body composition evaluation.
DESIGN: This study evaluated the 50 kHz BC-418 8-contact electrode and TBF-310 4-contact electrode foot-foot BIA systems (Tanita Corp., Tokyo, Japan).
SUBJECTS: There were 40 subject evaluations in males (n=20) and females (n=20) ranging in age from 6 to 64 y. BIA was evaluated in each subject and compared to reference lean soft-tissue (LST) and %fat estimates in the appendages and remainder (trunk+head) provided by dual-energy X-ray absorptiometry (DXA). Appendicular LST (ALST) estimates from both BIA and DXA were used to derive total body SM mass.
RESULTS: The highest correlation between total body LST by DXA and impedance index (Ht(2)/Z) by BC-418 was for the foot-hand segments (r=0.986; left side only) compared to the arm (r=0.970-0.979) and leg segments (r=0.942-0.957)(all P<0.001). The within- and between-day coefficient of variation for %fat and ALST evaluated in five subjects was <1% and approximately 1-3.7%, respectively. The correlations between 8-electrode predicted and DXA appendicular (arms, legs, total) and trunk+head LST were strong and highly significant (all r> or =0.95, P<0.001) and group means did not differ across methods. Skeletal muscle mass calculated (Kim equation) from total ALST by DXA (X+/-s.d.)(23.7+/-9.7 kg) was not significantly different and highly correlated with BC-418 estimates (25.2+/-9.6 kg; r=0.96, P<0.001). There was a good correlation between total body %fat by 8-electrode BIA vs DXA (r=0.87, P<0.001) that exceeded the corresponding association with 4-electrode BIA (r=0.82, P<0.001). Group mean segmental %fat estimates from BC-418 did not differ significantly from corresponding DXA estimates. No between-method bias was detected in the whole body, ALST, and skeletal muscle analyses.
CONCLUSIONS: The new 8-electrode BIA system offers an important new opportunity of evaluating SM in research and clinical settings. The additional electrodes of the new BIA system also improve the association with DXA %fat estimates over those provided by the conventional foot-foot BIA.

Entities:  

Mesh:

Year:  2004        PMID: 15138459     DOI: 10.1038/sj.ejcn.1601993

Source DB:  PubMed          Journal:  Eur J Clin Nutr        ISSN: 0954-3007            Impact factor:   4.016


  105 in total

1.  Prediction of whole-body and segmental body composition by bioelectrical impedance in morbidly obese subjects.

Authors:  Amanda Jiménez; Wilberto Omaña; Lílliam Flores; María José Coves; Diego Bellido; Verónica Perea; Josep Vidal
Journal:  Obes Surg       Date:  2012-04       Impact factor: 4.129

2.  Body fat reference curves for healthy Turkish children and adolescents.

Authors:  Selim Kurtoglu; Mumtaz Mustafa Mazicioglu; Ahmet Ozturk; Nihal Hatipoglu; Betul Cicek; Hasan Basri Ustunbas
Journal:  Eur J Pediatr       Date:  2010-05-27       Impact factor: 3.183

3.  Effects of aquatic resistance training on health and fitness in postmenopausal women.

Authors:  Juan C Colado; N Travis Triplett; Victor Tella; Pedro Saucedo; José Abellán
Journal:  Eur J Appl Physiol       Date:  2009-02-10       Impact factor: 3.078

4.  Combined effects of MC4R and FTO common genetic variants on obesity in European general populations.

Authors:  Stéphane Cauchi; Fanny Stutzmann; Christine Cavalcanti-Proença; Emmanuelle Durand; Anneli Pouta; Anna-Liisa Hartikainen; Michel Marre; Sylviane Vol; Tuija Tammelin; Jaana Laitinen; Arturo Gonzalez-Izquierdo; Alexandra I F Blakemore; Paul Elliott; David Meyre; Beverley Balkau; Marjo-Riitta Järvelin; Philippe Froguel
Journal:  J Mol Med (Berl)       Date:  2009-03-03       Impact factor: 4.599

5.  Changes in weight, body composition and physical fitness after 1.5 years at university.

Authors:  T Deliens; B Deforche; I De Bourdeaudhuij; P Clarys
Journal:  Eur J Clin Nutr       Date:  2015-05-27       Impact factor: 4.016

6.  Lipedema and Dercum's Disease: A New Application of Bioimpedance.

Authors:  Rachelle Crescenzi; Paula M C Donahue; Sandra Weakley; Maria Garza; Manus J Donahue; Karen L Herbst
Journal:  Lymphat Res Biol       Date:  2019-08-13       Impact factor: 2.589

7.  Validity of bioelectrical impedance analysis for measuring changes in body water and percent fat after bariatric surgery.

Authors:  Elizabeth M Widen; Gladys Strain; Wendy C King; Wenwen Yu; Susan Lin; Bret Goodpaster; John Thornton; Anita Courcoulas; Alfons Pomp; Dympna Gallagher
Journal:  Obes Surg       Date:  2014-06       Impact factor: 4.129

8.  The relation of metabolic syndrome according to five definitions to cardiovascular risk factors--a population-based study.

Authors:  Cheng-Chieh Lin; Chiu-Shong Liu; Chia-Ing Li; Wen-Yuan Lin; Ming-May Lai; Tsann Lin; Pei-Chia Chang; Yih-Dar Lee; Ching-Chu Chen; Chih-Hsueh Lin; Chuan-Wei Yang; Chih-Yi Hsiao; Walter Chen; Tsai-Chung Li
Journal:  BMC Public Health       Date:  2009-12-23       Impact factor: 3.295

9.  Sex difference in the association of metabolic syndrome with high sensitivity C-reactive protein in a Taiwanese population.

Authors:  Ming-May Lai; Chia-Ing Li; Sharon L R Kardia; Chiu-Shong Liu; Wen-Yuan Lin; Yih-Dar Lee; Pei-Chia Chang; Cheng-Chieh Lin; Tsai-Chung Li
Journal:  BMC Public Health       Date:  2010-07-21       Impact factor: 3.295

10.  Importance of dietary advice, nutritional supplements and compliance for maintaining body weight and body fat after hip fracture.

Authors:  Y Wengstrom; L K Wahren; E Grodzinsky
Journal:  J Nutr Health Aging       Date:  2009-08       Impact factor: 4.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.