Literature DB >> 15137335

Myocardial perfusion measurements by spin-labeling under different vasodynamic states.

Florian Fidler1, Christian M Wacker, Christian Dueren, Matthias Weigel, Peter M Jakob, Wolfgang R Bauer, Axel Haase.   

Abstract

In this study absolute myocardial perfusion was determined using a spin-labeling magnetic resonance imaging (MRI) technique at 2 Tesla. The technique was applied to 16 healthy volunteers at resting conditions, adenosine-induced stress, and oxygen breathing. Overall myocardial quantitative perfusion was determined as 2.3 +/- 0.8 mL/g/min (rest), 4.2 +/- 1.0 mL/g/min (adenosine), and 1.6 +/- 0.6 mL/g/min (oxygen), respectively. T1 of left ventricular blood pool decreased from 1709 +/- 101 ms (rest) to 1423 +/- 61 ms (oxygen), whereas T1 of right ventricular blood did not change significantly (1586 +/- 126 ms and 1558 +/- 150 ms). In conclusion, the presented technique for quantification of myocardial perfusion is an alternative to contrast agent-based methods. The spin labeling method is noninvasive and easily repeatable and it could therefore become an important tool to study changes in myocardial perfusion under different vasodynamic states.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15137335     DOI: 10.1081/jcmr-120030571

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


  6 in total

Review 1.  Magnetic resonance cardiac perfusion imaging-a clinical perspective.

Authors:  Peter Hunold; Thomas Schlosser; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2006-05-03       Impact factor: 5.315

Review 2.  Important advances in technology and unique applications related to cardiac magnetic resonance imaging.

Authors:  Mohamad G Ghosn; Dipan J Shah
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

3.  Orientation dependence of microcirculation-induced diffusion signal in anisotropic tissues.

Authors:  Osama M Abdullah; Arnold David Gomez; Samer Merchant; Michael Heidinger; Steven Poelzing; Edward W Hsu
Journal:  Magn Reson Med       Date:  2015-10-29       Impact factor: 4.668

4.  Improved arterial spin labeling after myocardial infarction in mice using cardiac and respiratory gated look-locker imaging with fuzzy C-means clustering.

Authors:  Moriel H Vandsburger; Robert L Janiczek; Yaqin Xu; Brent A French; Craig H Meyer; Christopher M Kramer; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

Review 5.  Emerging MRI methods in translational cardiovascular research.

Authors:  Moriel H Vandsburger; Frederick H Epstein
Journal:  J Cardiovasc Transl Res       Date:  2011-03-31       Impact factor: 4.132

6.  Stepped impedance resonators for high-field magnetic resonance imaging.

Authors:  Can E Akgun; Lance DelaBarre; Hyoungsuk Yoo; Sung-Min Sohn; Carl J Snyder; Gregor Adriany; Kamil Ugurbil; Anand Gopinath; J Thomas Vaughan
Journal:  IEEE Trans Biomed Eng       Date:  2014-02       Impact factor: 4.538

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.