Literature DB >> 15136622

Gated (99m)Tc-tetrofosmin SPECT for discriminating infarct from artifact in fixed myocardial perfusion defects.

Samuel Fleischmann1, Pascal Koepfli, Mehdi Namdar, Christophe A Wyss, Rolf Jenni, Philipp A Kaufmann.   

Abstract

UNLABELLED: Soft-tissue attenuation artifacts generally appear as fixed perfusion-scan defects. Gated (99m)Tc-tetrofosmin SPECT may help differentiate myocardial infarction (MI) from artifacts, as fixed defects with decreased function (wall motion and thickening) probably represent MI, whereas attenuation artifacts represent preserved function.
METHODS: Ungated stress and gated rest (99m)Tc-tetrofosmin SPECT was performed on 153 consecutive patients referred for evaluation of coronary artery disease. From stress and summed gated rest images, 107 patients (70%) were identified with isolated fixed defects. The function of the defects was assessed semiquantitatively from gated stress images. The findings were correlated with clinical (history or electrocardiographic Q waves) evidence of MI.
RESULTS: Of 62 patients with fixed defects and clinical MI, 60 (97%) had an abnormal defect function. Of 45 patients with no clinical MI, 16 (36%) had decreased function of the defect, possibly indicating silent MI. In 29 of the 45 patients (64%) with no clinical MI, defect function was normal. Because most (90%) fixed defects with normal systolic function occurred in men with inferior fixed defects (87%) or women with anterior fixed defects (3%), these were most likely attenuation artifacts. By reclassifying the condition of patients with fixed defects and normal function as normal, patients with unexplained fixed defects (no clinical MI) decreased from 29% to 10%.
CONCLUSION: Gating adds considerable value to (99m)Tc-tetrofosmin SPECT myocardial perfusion imaging in characterizing fixed defects and potentially improves test specificity.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15136622

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  20 in total

1.  President's message: Advocacy for nuclear cardiology--the self-referral issue.

Authors:  Kim A Williams
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

2.  Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT.

Authors:  Tiziano Schepis; Oliver Gaemperli; Pascal Koepfli; Christine Rüegg; Cyrill Burger; Sebastian Leschka; Lotus Desbiolles; Lars Husmann; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-08-04       Impact factor: 9.236

3.  Comparison of attenuation, dual-energy-window, and model-based scatter correction of low-count SPECT to 82Rb PET/CT quantified myocardial perfusion scores.

Authors:  R Glenn Wells; Karen Soueidan; Rachel Timmins; Terrence D Ruddy
Journal:  J Nucl Cardiol       Date:  2013-06-05       Impact factor: 5.952

4.  Prospective diagnostic performance of semiconductor SPECT myocardial perfusion imaging: wall thickening analysis reduces the need for an additional prone acquisition.

Authors:  Loïc Djaileb; Benjamin Dubois; Nicolas de Leiris; Julien Leenhardt; Marjorie Canu; Olivier Phan Sy; Adrien Carabelli; Bastien Boussat; Laurent Dumas; Alexis Broisat; Gérald Vanzetto; Daniel Fagret; Catherine Ghezzi; Gilles Barone-Rochette; Laurent M Riou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-18       Impact factor: 9.236

5.  Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: fewer equivocal results and lower radiation dose.

Authors:  Mohamed Mouden; Jorik R Timmer; Jan Paul Ottervanger; Stoffer Reiffers; Ad H J Oostdijk; Siert Knollema; Pieter L Jager
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-03-17       Impact factor: 9.236

6.  Validation of an automated method to quantify stress-induced ischemia and infarction in rest-stress myocardial perfusion SPECT.

Authors:  Helen Fransson; Michael Ljungberg; Marcus Carlsson; Henrik Engblom; Håkan Arheden; Einar Heiberg
Journal:  J Nucl Cardiol       Date:  2014-02-15       Impact factor: 5.952

7.  What is the value of motion and thickening in gated myocardial perfusion SPECT?

Authors:  Tali Sharir
Journal:  J Nucl Cardiol       Date:  2018-02-23       Impact factor: 5.952

8.  Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study.

Authors:  Dario Genovesi; Assuero Giorgetti; Alessia Gimelli; Annette Kusch; Irene D'Aragona Tagliavia; Mirta Casagranda; Giorgio Cannizzaro; Raffaele Giubbini; Francesco Bertagna; Giorgio Fagioli; Massimiliano Rossi; Annadina Romeo; Pietro Bertolaccini; Rita Bonini; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-06-09       Impact factor: 9.236

9.  Computerized left ventricular regional ejection fraction analysis for detection of ischemic coronary artery disease with multidetector CT angiography.

Authors:  Irfan Zeb; Dong Li; Khurram Nasir; Mohit Gupta; Jigar Kadakia; Yanlin Gao; Eva Ma; Song Shou Mao; Matthew Budoff
Journal:  Int J Cardiovasc Imaging       Date:  2012-09-14       Impact factor: 2.357

10.  Integrated assessment of coronary anatomy and myocardial perfusion using a retractable SPECT camera combined with 64-slice CT: initial experience.

Authors:  Christian Thilo; U Joseph Schoepf; Leonie Gordon; Salvatore Chiaramida; Jill Serguson; Philip Costello
Journal:  Eur Radiol       Date:  2008-10-30       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.