Literature DB >> 15135701

Usefulness of ultrasound lung comets as a nonradiologic sign of extravascular lung water.

Zoltan Jambrik1, Simonetta Monti, Vincenzo Coppola, Eustachio Agricola, Gaetano Mottola, Massimo Miniati, Eugenio Picano.   

Abstract

The "comet-tail" is an ultrasound sign detectable with ultrasound chest instruments; this sign consists of multiple comet-tails fanning out from the lung surface. They originate from water-thickened interlobular septa and would be ideal for nonradiologic bedside assessment of extravascular lung water. To assess the feasibility and value of ultrasonic comet signs, we studied 121 consecutive hospitalized patients (43 women and 78 men; aged 67 +/- 12 years) admitted to our combined cardiology-pneumology department (including cardiac intensive care unit); the study was conducted with commercially available echocardiographic systems including a portable unit. Transducer frequencies (range 2.5 to 3.5 MHz) were used. In each patient, the right and left chest was scanned by examining predefined locations in multiple intercostal spaces. Examiners blinded to clinical diagnoses noted the presence and numbers of lung comets at each examining site. A patient lung comet score was obtained by summing the number of comets in each of the scanning spaces. Within a few minutes, patients underwent chest x-ray, with specific assessment of extravascular lung water score by 2 pneumologist-radiologists blinded to clinical and echo findings. The chest ultrasound scan was obtained in all patients (feasibility 100%). The imaging time per examination was always <3 minutes. There was a linear correlation between echocardiographic comet score and radiologic lung water score (r = 0.78, p <0.01). Intrapatient variations (n = 15) showed an even stronger correlation between changes in echocardiographic lung comet and radiologic lung water scores (r = 0.89; p <0.01). In 121 consecutive hospitalized patients, we found a linear correlation between echocardiographic comet scores and radiologic extravascular lung water scores. Thus, the comet-tail is a simple, non-time-consuming, and reasonably accurate chest ultrasound sign of extravascular lung water that can be obtained at bedside (also with portable echocardiographic equipment) and is not restricted by cardiac acoustic window limitations.

Entities:  

Mesh:

Year:  2004        PMID: 15135701     DOI: 10.1016/j.amjcard.2004.02.012

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  126 in total

Review 1.  Pediatric chest ultrasound: a practical approach.

Authors:  Mougnyan Cox; Michalle Soudack; Daniel J Podberesky; Monica Epelman
Journal:  Pediatr Radiol       Date:  2017-08-04

Review 2.  International evidence-based recommendations for point-of-care lung ultrasound.

Authors:  Giovanni Volpicelli; Mahmoud Elbarbary; Michael Blaivas; Daniel A Lichtenstein; Gebhard Mathis; Andrew W Kirkpatrick; Lawrence Melniker; Luna Gargani; Vicki E Noble; Gabriele Via; Anthony Dean; James W Tsung; Gino Soldati; Roberto Copetti; Belaid Bouhemad; Angelika Reissig; Eustachio Agricola; Jean-Jacques Rouby; Charlotte Arbelot; Andrew Liteplo; Ashot Sargsyan; Fernando Silva; Richard Hoppmann; Raoul Breitkreutz; Armin Seibel; Luca Neri; Enrico Storti; Tomislav Petrovic
Journal:  Intensive Care Med       Date:  2012-03-06       Impact factor: 17.440

3.  3D superhydrophobic electrospun meshes as reinforcement materials for sustained local drug delivery against colorectal cancer cells.

Authors:  Stefan T Yohe; Victoria L M Herrera; Yolonda L Colson; Mark W Grinstaff
Journal:  J Control Release       Date:  2012-06-06       Impact factor: 9.776

4.  Emerging roles for transthoracic ultrasonography in pulmonary diseases.

Authors:  Sergio Sartori; Paola Tombesi
Journal:  World J Radiol       Date:  2010-06-28

5.  Bioimpedance analysis versus lung ultrasonography for optimal risk prediction in hemodialysis patients.

Authors:  Dimitrie Siriopol; Luminita Voroneanu; Simona Hogas; Mugurel Apetrii; Angelica Gramaticu; Raluca Dumea; Alexandru Burlacu; Radu Sascau; Mehmet Kanbay; Adrian Covic
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-01       Impact factor: 2.357

6.  A hand-carried cardiac ultrasound device in the outpatient cardiology clinic reduces the need for standard echocardiography.

Authors:  P Trambaiolo; F Papetti; A Posteraro; E Amici; M Piccoli; E Cerquetani; G Pastena; G Gambelli; A Salustri
Journal:  Heart       Date:  2006-08-29       Impact factor: 5.994

7.  Ultrasound lung "comets" increase after breath-hold diving.

Authors:  Kate Lambrechts; Peter Germonpré; Brian Charbel; Danilo Cialoni; Patrick Musimu; Nicola Sponsiello; Alessandro Marroni; Frédéric Pastouret; Costantino Balestra
Journal:  Eur J Appl Physiol       Date:  2010-10-23       Impact factor: 3.078

8.  Shirt fold mimicking pneumothorax on chest radiograph: accurate diagnosis by ultrasound.

Authors:  F R Silva
Journal:  Intern Emerg Med       Date:  2007-10-01       Impact factor: 3.397

9.  Acute heart failure: new diagnostic perspectives for the emergency physician.

Authors:  Gino Soldati; Luna Gargani; Fernando R Silva
Journal:  Intern Emerg Med       Date:  2008-02-09       Impact factor: 3.397

10.  The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study.

Authors:  Claudia Torino; Luna Gargani; Rosa Sicari; Krzysztof Letachowicz; Robert Ekart; Danilo Fliser; Adrian Covic; Kostas Siamopoulos; Aristeidis Stavroulopoulos; Ziad A Massy; Enrico Fiaccadori; Alberto Caiazza; Thomas Bachelet; Itzchak Slotki; Alberto Martinez-Castelao; Marie-Jeanne Coudert-Krier; Patrick Rossignol; Faikah Gueler; Thierry Hannedouche; Vincenzo Panichi; Andrzej Wiecek; Giuseppe Pontoriero; Pantelis Sarafidis; Marian Klinger; Radovan Hojs; Sarah Seiler-Mussler; Fabio Lizzi; Dimitrie Siriopol; Olga Balafa; Linda Shavit; Rocco Tripepi; Francesca Mallamaci; Giovanni Tripepi; Eugenio Picano; Gérard Michel London; Carmine Zoccali
Journal:  Clin J Am Soc Nephrol       Date:  2016-09-22       Impact factor: 8.237

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.