| Literature DB >> 15135106 |
Wonku Kang1, Hwi-Yeol Yun, Kwang-Hyeon Liu, Kwang-Il Kwon, Jae-Gook Shin.
Abstract
We developed a method for determining benidipine, a dihydropyridine analogue calcium-channel blocker, in plasma using liquid chromatography-tandem mass spectrometry (LC-MS-MS). Benidipine and benidipine-d5, an internal standard, were extracted from plasma using diethyl ether in the presence of 5M NaOH. After drying the organic layer, the residue was reconstituted in acetonitrile and injected onto a reversed-phase C18 column. The isocratic mobile phase (acetonitrile-5mM ammonium acetate, 90:10, v/v) was eluted at 0.2 ml/min. The ion transitions monitored in multiple reaction-monitoring mode were m/z 506-174 for benidipine and m/z 511-179 for the internal standard. The coefficient of variation of the assay precision was less than 13%, and the accuracy exceeded 92%, except at the limit of quantification, 0.05 ng/ml with 1ml of plasma, when it was 85%. This method was used to measure the benidipine concentration in plasma from healthy subjects after a single 4-mg oral dose of benidipine. This method is a very simple, sensitive, and accurate way to determine the plasma benidipine concentration.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15135106 DOI: 10.1016/j.jchromb.2004.03.023