Successful treatment for exposure of a dacron aorta, with surrounding infection: case report.

J V Hugill, J W Curtin.   

Abstract

The treatment of the patient with an exposed vascular implant should usually be in the hands of an expert vascular surgeon. In certain instances, such as when the exposed area is not close to a suture line and no fistulous tracts connect the exposed area to either suture line, plastic surgery can solve the problem. We present a case of an exposed aortic prosthesis which was successfully treated by removing devitalized tissue, turning a pectoralis major muscle flap over the implant, and closing the skin and subcutaneous tissue over the muscle flap.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 151297     DOI: 10.1097/00006534-197809000-00031

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730