Literature DB >> 15129698

Comparison of methodologies for the in vivo assessment of 18FLT utilisation in colorectal cancer.

D Visvikis1, D Francis, R Mulligan, D C Costa, I Croasdale, S K Luthra, I Taylor, P J Ell.   

Abstract

Fluorine-18 3'-deoxy-3'-fluorothymidine (18FLT) is a tissue proliferation marker which has been suggested as a new tumour-specific imaging tracer in positron emission tomography (PET). The objectives of this study were to investigate the pharmacokinetics of 18FLT in patients with colorectal cancer, defining methodologies for the quantitative analysis of the in vivo 18FLT uptake and subsequently assessing the accuracy of semi-quantitative measures. Dynamic acquisitions over a single field of view of interest identified by computed tomography were carried out for up to 60 min following injection of 18FLT (360 +/- 25 MBq). Dynamic arterial blood sampling was carried out in order to provide a blood input function. Simultaneous venous samples were also taken in order to investigate their potential utilisation in deriving a hybrid input function. Arterial and venous blood samples at 5, 15, 30, 60 and 90 min p.i. were used for metabolite analysis. Eleven patients with primary and/or metastatic colorectal cancer were studied on a lesion by lesion basis (n = 21). All acquired images were reconstructed using ordered subsets expectation maximisation and segmented attenuation correction. Time-activity curves were derived by image region of interest (ROI) analysis and image-based input functions were obtained using abdominal or thoracic aorta ROIs. Standardised uptake values (SUVs) were calculated to provide semi-quantitative indices of uptake, while non-linear regression (NLR) methodology in association with a three-compartment model and Patlak analysis were carried out to derive the net influx constant Ki. The metabolite analysis revealed two radioactive metabolites, with the parent compound representing approximately 80% of the total radioactivity in the 30-min plasma sample. In the case of NLR, better fits were obtained with a 3k model (i.e. k4 = 0) for both lesion and bone marrow time-activity curves. For the same lesions, a high correlation was observed between the Ki derived from either Patlak analysis or NLR(3k) and the corresponding SUVs. Our results also suggest that the quantitative behaviour of 18FLT in vivo (up to 60 min p.i.) may be characterised using a 3k model or Patlak analysis in combination with image-derived input functions. The good correlation found between the SUVs (at 60 min) and Ki values supports the use of semi-quantitative indices to assess the proliferation rate of colorectal cancer lesions in vivo with 18FLT.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15129698     DOI: 10.1007/s00259-003-1339-2

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  33 in total

1.  Use of the abdominal aorta for arterial input function determination in hepatic and renal PET studies.

Authors:  G Germano; B C Chen; S C Huang; S S Gambhir; E J Hoffman; M E Phelps
Journal:  J Nucl Med       Date:  1992-04       Impact factor: 10.057

2.  Focal fluorine-18 fluorodeoxyglucose accumulation in inflammatory pancreatic disease.

Authors:  P D Shreve
Journal:  Eur J Nucl Med       Date:  1998-03

3.  Patterns of recurrence after curative resection of carcinoma of the colon and rectum.

Authors:  S Galandiuk; H S Wieand; C G Moertel; S S Cha; R J Fitzgibbons; J H Pemberton; B G Wolff
Journal:  Surg Gynecol Obstet       Date:  1992-01

4.  A PET study of 18FDG uptake in soft tissue masses.

Authors:  M A Lodge; J D Lucas; P K Marsden; B F Cronin; M J O'Doherty; M A Smith
Journal:  Eur J Nucl Med       Date:  1999-01

Review 5.  Selection of patients for resection of hepatic metastases: improved detection of extrahepatic disease with FDG pet.

Authors:  I A Zealley; S J Skehan; J Rawlinson; G Coates; C Nahmias; S Somers
Journal:  Radiographics       Date:  2001-10       Impact factor: 5.333

6.  Performance characteristics of a whole-body PET scanner.

Authors:  T R DeGrado; T G Turkington; J J Williams; C W Stearns; J M Hoffman; R E Coleman
Journal:  J Nucl Med       Date:  1994-08       Impact factor: 10.057

7.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations.

Authors:  C S Patlak; R G Blasberg
Journal:  J Cereb Blood Flow Metab       Date:  1985-12       Impact factor: 6.200

8.  Value of positron emission tomography with [F-18]fluorodeoxyglucose in patients with colorectal liver metastases: a prospective study.

Authors:  T J M Ruers; B S Langenhoff; N Neeleman; G J Jager; S Strijk; Th Wobbes; F H M Corstens; W J G Oyen
Journal:  J Clin Oncol       Date:  2002-01-15       Impact factor: 44.544

9.  Tumor metabolic rates in sarcoma using FDG PET.

Authors:  J F Eary; D A Mankoff
Journal:  J Nucl Med       Date:  1998-02       Impact factor: 10.057

10.  3-deoxy-3-[(18)F]fluorothymidine-positron emission tomography for noninvasive assessment of proliferation in pulmonary nodules.

Authors:  Andreas K Buck; Holger Schirrmeister; Martin Hetzel; Mareike Von Der Heide; Gisela Halter; Gerhard Glatting; Torsten Mattfeldt; Florian Liewald; Sven N Reske; Bernd Neumaier
Journal:  Cancer Res       Date:  2002-06-15       Impact factor: 12.701

View more
  27 in total

Review 1.  Plasma radiometabolite correction in dynamic PET studies: Insights on the available modeling approaches.

Authors:  Matteo Tonietto; Gaia Rizzo; Mattia Veronese; Masahiro Fujita; Sami S Zoghbi; Paolo Zanotti-Fregonara; Alessandra Bertoldo
Journal:  J Cereb Blood Flow Metab       Date:  2015-10-14       Impact factor: 6.200

2.  The role of 18F-FLT in cancer imaging: does it really reflect proliferation?

Authors:  Antonia Dimitrakopoulou-Strauss; Ludwig G Strauss
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-03       Impact factor: 9.236

Review 3.  Image-derived input function for brain PET studies: many challenges and few opportunities.

Authors:  Paolo Zanotti-Fregonara; Kewei Chen; Jeih-San Liow; Masahiro Fujita; Robert B Innis
Journal:  J Cereb Blood Flow Metab       Date:  2011-08-03       Impact factor: 6.200

4.  Heterogeneity in stabilization phenomena in FLT PET images of canines.

Authors:  Urban Simoncic; Robert Jeraj
Journal:  Phys Med Biol       Date:  2014-11-26       Impact factor: 3.609

5.  Clinical relevance of imaging proliferative activity in lung nodules.

Authors:  Andreas K Buck; Martin Hetzel; Holger Schirrmeister; Gisela Halter; Peter Möller; Clemens Kratochwil; Andreas Wahl; Gerhard Glatting; Felix M Mottaghy; Torsten Mattfeldt; Bernd Neumaier; Sven N Reske
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-12-14       Impact factor: 9.236

6.  Combined imaging biomarkers for therapy evaluation in glioblastoma multiforme: correlating sodium MRI and F-18 FLT PET on a voxel-wise basis.

Authors:  Charles M Laymon; Matthew J Oborski; Vincent K Lee; Denise K Davis; Erik C Wiener; Frank S Lieberman; Fernando E Boada; James M Mountz
Journal:  Magn Reson Imaging       Date:  2012-07-21       Impact factor: 2.546

7.  A simplified analysis of [18F]3'-deoxy-3'-fluorothymidine metabolism and retention.

Authors:  Anthony F Shields; David A Briston; Samatha Chandupatla; Kirk A Douglas; Jawana Lawhorn-Crews; Jerry M Collins; Thomas J Mangner; Lance K Heilbrun; Otto Muzik
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07-01       Impact factor: 9.236

8.  A pilot study of the value of 18F-fluoro-deoxy-thymidine PET/CT in predicting viable lymphoma in residual 18F-FDG avid masses after completion of therapy.

Authors:  Esther Mena; Maria Liza Lindenberg; Baris I Turkbey; Joanna Shih; Jean Logan; Stephen Adler; Karen Wong; Wyndham Wilson; Peter L Choyke; Karen A Kurdziel
Journal:  Clin Nucl Med       Date:  2014-10       Impact factor: 7.794

9.  Dynamic small-animal PET imaging of tumor proliferation with 3'-deoxy-3'-18F-fluorothymidine in a genetically engineered mouse model of high-grade gliomas.

Authors:  Michelle S Bradbury; Dolores Hambardzumyan; Pat B Zanzonico; Jazmin Schwartz; Shangde Cai; Eva M Burnazi; Valerie Longo; Steven M Larson; Eric C Holland
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

10.  Quantitative accuracy of PET/CT for image-based kinetic analysis.

Authors:  Youngho Seo; Boon-Keng Teo; Mohiuddin Hadi; Carole Schreck; Stephen L Bacharach; Bruce H Hasegawa
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.