Paraspinal skin temperature patterns: an interexaminer and intraexaminer reliability study.

Edward F Owens1, John F Hart, Joseph J Donofrio, Jason Haralambous, Eric Mierzejewski.   

Abstract

BACKGROUND: Paraspinal thermography is used by chiropractors as an aid in assessing the presence of vertebral subluxation. Few reliability studies have been carried out, with mixed results. Digital infrared scanning equipment is now available with location tracking that may enhance reproducibility. Digitized scans enable a computer-aided interpretation of thermographic patterns.
OBJECTIVE: To assess the ability of examiners to reproduce thermal patterns. STUDY
DESIGN: Repeated measures with 2 examiners assessing the same patient on 2 occasions. Thirty asymptomatic students served as subjects.
METHODS: A TyTron C-3000 handheld thermographic scanner interfaced to a Microsoft Windows compatible personal computer was used for all recordings. Each examiner recorded 2 scans on each patient. It took an average of 3 minutes to complete all 4 scans. Data were exported to a spreadsheet for initial analysis, then SPSS was used for calculation of intraclass correlation coefficients (ICC). Since the starting and stopping points of scans were not always the same, care was taken to align scans visually, using well-distinguished peaks on the charts as guides. Scans were cropped to remove artifacts that might have occurred at the beginning and end of the scans. Intraexaminer and interexaminer ICCs were calculated.
RESULTS: Skin temperatures ranged from 35.4 degrees C to 30.0 degrees C over all scans. The average temperatures changed little from the first to the last scans, indicating that subjects' overall skin temperatures were stable during the scanning procedure. Intraexaminer ICCs ranged from 0.953 to 0.984. The left and right channel data show slightly higher congruence than the Delta channel. The interexaminer reliability coefficients ranged from 0.918 to 0.975. Again, the Delta channel shows slightly less reliability, although the ICCs were quite high for all channels.
CONCLUSION: Intraexaminer and interexaminer reliability of paraspinal thermal scans using the TyTron C-3000 were found to be very high, with ICC values between 0.91 and 0.98. Changes seen in thermal scans when properly done are most likely due to actual physiological changes rather than equipment error.

Entities:  

Mesh:

Year:  2004        PMID: 15129197     DOI: 10.1016/j.jmpt.2003.12.019

Source DB:  PubMed          Journal:  J Manipulative Physiol Ther        ISSN: 0161-4754            Impact factor:   1.437


  16 in total

1.  Reliability of three methods of computer-aided thermal pattern analysis.

Authors:  John Hart; Bernard Omolo; W R Boone; Charlene Brown; Andrew Ashton
Journal:  J Can Chiropr Assoc       Date:  2007

2.  Craniocervical chiropractic procedures - a précis of upper cervical chiropractic.

Authors:  H Charles Woodfield; Craig York; Roderic P Rochester; Scott Bales; Mychal Beebe; Bryan Salminen; Jeffrey N Scholten
Journal:  J Can Chiropr Assoc       Date:  2015-06

3.  Inter-examiner reliability of the interpretation of paraspinal thermographic pattern analysis.

Authors:  Barbara A Mansholt; Robert D Vining; Cynthia R Long; Christine M Goertz
Journal:  J Can Chiropr Assoc       Date:  2015-06

4.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

5.  Reliability of infrared thermography in skin temperature evaluation of wheelchair users.

Authors:  I Rossignoli; P J Benito; A J Herrero
Journal:  Spinal Cord       Date:  2014-11-25       Impact factor: 2.772

6.  Inflammatory response following a short-term course of chiropractic treatment in subjects with and without chronic low back pain.

Authors:  Richard A Roy; Jean P Boucher; Alain S Comtois
Journal:  J Chiropr Med       Date:  2010-09

7.  Cooling efficiency of 4 common cryotherapeutic agents.

Authors:  Jane Kennet; Natalie Hardaker; Sarah Hobbs; James Selfe
Journal:  J Athl Train       Date:  2007 Jul-Sep       Impact factor: 2.860

8.  The Chiropractic Vertebral Subluxation Part 1: Introduction.

Authors:  Simon A Senzon
Journal:  J Chiropr Humanit       Date:  2019-04-06

9.  Detection of skin temperature differences using palpation by manual physical therapists and lay individuals.

Authors:  David Levine; J Randy Walker; Denis J Marcellin-Little; Ron Goulet; Hongyu Ru
Journal:  J Man Manip Ther       Date:  2018-01-22

10.  THE EFFECT OF KNEE JOINT COOLING ON ISOKINETIC TORQUE PRODUCTION OF THE KNEE EXTENSORS: CONSIDERATIONS FOR APPLICATION.

Authors:  David Rhodes; Jill Alexander
Journal:  Int J Sports Phys Ther       Date:  2018-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.